All four outputs on a production board need 100 MHz, so a supplier treats different CDCE6214 startup modes as equivalent. In TI's factory example with a 25 MHz crystal, page zero produces LP-HCSL and page one produces LVDS. Frequencies match, but interface and control modes differ. Page one uses the serial interface, while page zero uses pin mode. Both can show 100 MHz on a frequency counter.
Check the control pins as power comes up
Check actual pulls and soldering on HW_SW_CTRL and REF_SEL and when the external controller takes over. The page-selection instructions say REF_SEL must not float. Particular conditions, such as relevant pins in high impedance, can select fallback mode. Levels after software starts cannot establish the page selected at power-up. For a custom-programmed order, obtain its actual configuration file and avoid relying on generic factory examples.
Test without software correcting the result
Use a production-configured sample board, leave the programming tool disconnected, and fully power-cycle. Connect the correct termination for the expected output standard and record each waveform, lock indication, and serial-interface behavior. If a pin that should be quiet instead outputs a reference, check the mode table. If debug software has overwritten settings, retain both that result and a separate unassisted boot capture.
Specify the fitted strap option, EEPROM revision, and output interface together as a BOM variant. Production can verify the intended waveform and state, then identify incoming part, assembly, or preprogramming deviations rather than classifying everything as a frequency error. TI CDCE6214 factory preset pages and fallback mode