A powered oscillator has to clock both 1.8 V sampling logic and 3.3 V controller logic. The proposed buffer says it supports several output voltages, so the designer expects to select the voltage for each output. Check how the output supply pins are grouped. A list of supported voltages can apply to the entire device. If there are independent output domains, check the number of outputs and supply restrictions for each one.
Assign loads by output supply bank
The input, driver, and control portions of a simple buffer may all use one supply. It may support several supply voltages, but on any one board its outputs follow the selected supply. Other parts separate the core supply and output driver supply. Some also split the outputs into banks with their own supply pins. That lets a designer put the 1.8 V loads in one bank and the 3.3 V loads in another. Confirm the supply pins, block diagram, and pin names in the specific data sheet.
TI's LMK00101 data sheet groups outputs 0–4 in bank A and 5–9 in bank B. The banks may use different supplies, with no output supply higher than the core supply. It also says VDDO pins for the same bank are connected inside the package and should not be left open or tied to ground. Two pins for the same bank cannot be connected to 1.8 V and 3.3 V separately. Trace each supply pin, including those behind filters, to make sure the board does not join two regulators.
Certain buffers can select among differential output types. The driver supply voltage and measured swing are separate quantities. For LVDS, LVPECL, and current-steering outputs, the topology and specified termination help set the swing. Separate supply banks enable supported operating points. Check receiver thresholds, common mode, and termination for the chosen interface. If changing the interface standard, check selection pins and termination drawings for the bank as well.
Count what fits in each bank
Suppose four sampling modules need a 1.8 V LVCMOS clock and three controller modules need 3.3 V. With two independently supplied banks of five outputs, use four outputs from bank A at 1.8 V and three from bank B at 3.3 V. Supply the core as permitted and handle the three unused outputs according to the data sheet. A spare output in bank B will still use 3.3 V. If the number of sampling modules grows from four to six, ten total outputs would cover nine loads, but bank A cannot serve six. Choose another bank arrangement or add a device.
Review the startup sequence. For the example part, arrange the 3.3 V core and 3.3 V output bank supplies in a manner allowed by the data sheet. Independent regulators can let the output bank temporarily exceed the core during startup or shutdown. Check the limit and the manufacturer's recommended arrangement. Capture the supply voltages at the pins across an actual power cycle and review enable and receiver safety while other domains are still coming up.
Check signal quality on the longer clock routes separately. Output resistance, load, and receiver thresholds can differ between banks, so propagation delay can differ at the same frequency. If comparing edges across banks, look for applicable same-bank and bank-to-bank skew data with different supplies. Measure near the receiving pins to check levels, edges, and relative delays. If only one bank changes voltage, retest the other too because both share the core and some internal resources.
Record the details that change board wiring
For each output, record pin, bank, supply, receiver load, termination, and expected signal range. Mark configuration strap defaults. Request the vendor's supported supply combinations and bank capabilities when approving samples. A substitute with a shared output supply can require separate level conversion. Compare that circuit cost alongside the component price.
Keep a repeatable boundary test. Capture each supply from power-up to shutdown and compare both output banks with the same receiving conditions. Exercise the heaviest production load, including any change of one bank's supply that disturbs the other. Put the approved banks and external networks in the production connection table so new clock destinations can be checked before routing.
Provide a point to measure each bank supply. If one bank's high level is too low, first check for drops at its supply pads, then trace termination, load, and output settings. A supply fault can interact with core protection paths. A working output from the other bank alone does not clear it. With a filter resistor or bead, record voltage and transients on both sides.