Why is the first clock pulse narrower when a buffer is enabled?

A powered oscillator runs continuously, and the board uses a clock buffer's enable pin to deliver the clock when needed. After substituting a buffer in the same package, frequency and steady-state duty cycle still match. A receiver counter sometimes misses a count, and the scope shows an unusually narrow first pulse. Check when enable takes effect. A buffer that opens its output midway through an input period may pass only the end of the first high level. The data sheet's enable timing tells you whether the device prioritizes response time or preserves a complete pulse.

Identical truth tables can hide different timing

Two TI buffers whose names differ by an A provide a direct example. LMK1C1104 uses synchronous output enable, with enable and disable timing defined against the input waveform. Section 8.3.2 of the LMK1C1104A data sheet describes asynchronous output enable. With the asynchronous part, if the input is already held high, the powered device can drive its output high when enabled without waiting for another input edge. The static truth tables can show low when disabled and following the input when enabled for both parts. Use the truth table for wiring and polarity and the timing diagram for the first pulse.

Asynchronous enable lets the output follow the input promptly. A controller unrelated to the oscillator can assert enable at any point in the input high interval. If the output starts following halfway through, its high time depends on how much of that interval remains. Synchronous enable uses specified input cycles to open the output and is suitable when the design needs a synchronized transition. It takes time to wait for those cycles. A system that must immediately reflect a static input can find that wait undesirable. Compare full ordering codes against the actual transition the design needs.

Keep three observation points separate. The source generates a steady clock. The buffer decides when to pass it. The receiver has its own thresholds and minimum pulse width. An automatic scope frequency measurement drawn from many identical later cycles can establish steady-state frequency while missing the first-pulse problem. Trigger on the real enable signal and retain both input and receiver waveforms. Read the pulse at the thresholds specified for the receiver.

Worked example: Only 2 ns of a 10 ns high interval passes

Assume a 50 MHz input with 50% duty cycle, a 20 ns period, and a high interval from 0 to 10 ns. Enable goes high at 8 ns. Ignoring the difference between the buffer's internal propagation paths, the asynchronous output rises then falls with the input. The first high pulse lasts about 2 ns. If the receiver requires at least 4 ns, that pulse is outside its guarantee even if some samples register it. The next high interval returns to 10 ns, so a regular measurement window can still report nearly nominal frequency and duty cycle. The 8 ns position and 4 ns limit are example assumptions.

Sweep the enable phase or use two independent sources that produce enough relative positions in the range of interest. Start each run with the output disabled and the input still running. Record the buffer input, enable, receiver pin, and downstream count. Separate the time to the first output transition from the time to the first cycle that meets both high and low pulse limits. At disable, also check whether the last pulse is shortened. If shutdown timing matters, define whether the downstream logic must accept that last pulse. Apply the data sheet's waveform method so a single propagation delay is not mistaken for enable time.

Even when all receivers stay in reset before startup, review who coordinates reset and output enable and which edge the receiver first sees after reset release. A design can release reset after enough valid edges. If the controller waits a fixed time from the enable command, include the slowest input period, supply settling, and upper limits on device delay. If the receiver cannot mask its input, a suitably synchronized buffer or dedicated clock gate gives a behavior that can be tested against defined limits. Tying enable high by default does not address the first and last pulses when software actually operates the gate.

Retest start and stop timing with the alternate part

Mark the enable signal's clock domain, earliest transition, and the point at which downstream logic starts to recognize the clock. Keep the complete buffer part number, synchronous or asynchronous behavior, disabled level, and both timing definitions in the purchasing record. For a design that values quick response, test the delay using the device definition. For one that needs full edges, record the shortest pulse and receiver behavior across the relevant phases. Evaluate equivalents with the same input and load on the same board. Attach enable transition and reset evidence even if steady-state readings match.

If the trigger setup misses the first transition, start the acquisition before enable and include the complete first pulse. Save the capture conditions, including source duty cycle, load, and supply. The record then shows which boundaries to retest if the oscillator frequency or software enable timing later changes.

References