Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Measurement and Acceptance

How can reflection timing locate an intermittent oscillator fixture fault?

An active oscillator in a test socket occasionally shows a second step after its rising edge. Replacing the device makes no difference, but reconnecting the extension cable changes the waveform. Take the fixture out of powered production operation and check coax, connectors and transitions by time-domain reflectometry (TDR). TDR sends a fast step down the path and measures when a reflection returns. The delay gives a clue to the mismatch location. That lets you investigate the fixture before rejecting the oscillator.

Read an open, a short and a real transition

A 50 Ω line feeding a matched port ideally absorbs the incident wave without an appreciable reflection. A nearly open endpoint reflects with the same polarity as the incident wave, while a near-short reflects with opposite polarity. Tektronix illustrates both and relates reflection amplitude to impedance. A real connector or pad has inductance, capacitance and finite length. It may cause a bump followed by a dip, or the reverse. Use the physical location and compare connector replacement or reconnection, since the polarity alone does not identify the component.

Time on a coax includes the outbound and return paths. If the instrument displays distance, check which velocity factor it uses. A PCB trace, feedthrough or second cable material may propagate at a different speed. Establish time zero using the fixture drawing and a known length of similar cable, then identify the relevant section. If velocity is unknown, first compare the drawing and timing on good and suspect fixtures to narrow the physical search. The speed of light in air cannot be used for the whole path.

Worked example with assumed values. Suppose velocity is about three fifths of the speed of light, or 0.18 m/ns. A repeatable reflection 12 ns after the calibration reference corresponds to a 2.16 m round trip, or about 1.08 m one-way. If an adapter is roughly 1 m from the reference, replace it and retest first. Verify the real velocity from the cable specification or a known length. A reflection 2 ns later than the good fixture would indicate about 0.18 m greater one-way distance in the same medium. This conversion can help verify what changed after replacing a cable.

Compare good and suspect fixtures under identical conditions

Remove any device that could be affected by the injected step. State whether the test endpoint is open, shorted or terminated by the prescribed low-voltage test load. Check allowable stimulus and isolation for active circuits. Capture a normal baseline and use known open and matched standards to verify time reference and amplitude. On the same channel with the same stimulus and cable position, swap only the suspect extension or adapter. If the new reflection follows it, check its contact, solder joint or impedance transition. If a reflection is intermittent, gently move only the fixture’s intended movable section and see whether the trace follows.

With several impedance changes, a reflection can encounter an earlier mismatch and create a secondary echo. A late spike may represent multiple trips between two structures. Find the earliest difference and use changed terminations or shorter segments to separate causes. A bad first connection also affects visibility farther down the line. For fixtures with amplifiers, DC blocks, resistive networks or protection parts, diagram the test path and mark intentional reflections. Keep an empty-fixture comparison. Removing a designed calibration echo does not establish a fix.

Verify the repair using the clock

After repairing a connector or fixture, restore the approved termination and device. Capture oscillator edges, overshoot and logic threshold crossings. A TDR trace characterizes particular structures in the test path. If clock amplitude is still different, check output load and acquisition conditions. Run a retained sample on the repaired fixture and compare it with a healthy station before deciding which prior measurements need to be repeated. Record cable type, velocity setting, reference plane and actual distance to adapters. Purchasing can use that evidence when replacing a part or changing its specification.

Number adapters and mark the length of every coax segment. Check the first section with a standard termination before adding intermediate adapters one at a time. Each adapter may add a small step. Investigate the one that changes abruptly compared with the good fixture. If repair includes shortening a cable, verify termination again. A shifted echo may otherwise be mistaken for a vanished one. Once the fixture is reassembled, secure connections and record their condition.

For maintenance, mark a few known reflection times on the connector drawing. Keep the reference waveform, endpoint condition and raw data after each repair. The ability to distinguish nearby structures changes with step speed. Repeat at the same stimulus and record length before tying a waveform feature to a physical location.

References