Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Measurement and Acceptance

Two 50 MHz clocks differ by 400 ps. How do you measure the probe skew first?

One 50 MHz differential oscillator feeds two buffered paths. Probe both receivers at the same time, and the scope might show B arriving 400 ps after A. A 50 MHz clock has a 20 ns period, so 400 ps is 2% of a cycle, or about 7.2°. A delay difference of that size in the tips, accessories, cables or scope channels can change the apparent order of arrival. First move both probes to a suitable common-edge fixture. Measure the timing difference between the complete measurement chains and save that reference capture.

Use one edge and the same conditions for both measurement chains

Label the board paths A and B. Start with channel 1 on A and channel 2 on B, and define a positive result as B arriving later. Use a differential deskew fixture suitable for the probes to present the same rising differential edge with the same polarity at both probe tips. Connect positive to positive and negative to negative. When a generator feeds the probe positions through separate branches, check the electrical delay of those branches. Any unaccounted fixture delay becomes part of the measured offset and will be subtracted from the board result. Keep the tips and accessories, input ranges, bandwidth and coupling used for the board. Match the fixture signal's amplitude, edge slew and common-mode voltage to the intended measurement where practical. Check the probe's differential and common-mode input limits. Tektronix deskew fixture instructions for differential probes, Tektronix differential probe input range example.

Use one acquisition for both timestamps and measure the rising zero crossing of V+ − V−. Check for clipping. Collect enough repeats to record the average offset, the spread and unusual observations. Ringing can produce several crossings on one edge. Inspect the termination, probe connection and waveform, then define the valid crossing according to the test method. If the requirement calls for a receiver threshold, record the threshold used. On signals with offset or unequal swings, the differential zero crossing, the midpoint of each waveform and the receiver's threshold can occur at different times.

Record the automatic and manual deskew settings already in effect. For software subtraction, keep the same settings for both the fixture and board captures so the fixture reading describes the residual offset under those settings. For correction on the scope, select channel 1 as a reference, adjust the delay until the common edges align and save a fresh capture. The direction of adjustment is best verified from the alignment itself. Recheck the common-edge residual when the probes, tips, channels, ranges or bandwidth change. The nominal propagation delay in a probe's data can give you an initial setting. The fixture checks the measurement chain as connected. Tektronix probe and cable delay compensation, Keysight example of deskewing channels with a common signal.

Subtract the signed offset once and check it with a swap

For a worked example, suppose channel 2 minus channel 1 reads +150 ps on the common-edge fixture and +400 ps on the board with the same deskew settings. The estimated board path difference is +400 − (+150) = +250 ps, so B arrives about 250 ps later. If the fixture reading were −150 ps, the same +400 ps board reading would correct to +550 ps. Once the scope has removed the common-edge offset and the residual has been checked, report the corrected board reading. Mark the original and adjusted captures so anyone checking the calculation can track which correction was applied.

Physically swap the complete measurement chains. Leave each probe, cable and scope channel together and move the measurement tips between the two board points. Keep the correction settings the same. Continue to calculate B minus A, which after the swap is channel 1 minus channel 2. Suppose the two readings are +400 ps before the swap and +100 ps after it. If the probes have negligible effect on the board edges, the mean, (400 + 100) ÷ 2 = +250 ps, estimates the board path difference. The half difference, (400 − 100) ÷ 2 = +150 ps, estimates the measurement-chain skew. Check it against the fixture reading. If the waveform amplitude, slew rate or ringing changes with the swap, recheck loading, contact locations, termination and polarity before relying on that model.

Include the measurement uncertainty in the acceptance decision

Enable the channels needed for the test, then check the effective sample rate, the crossing slew on both traces and the conditions attached to the instrument's delta-time specification. At 20 GS/s, the sample interval is 50 ps, so 250 ps spans five sample intervals. Interpolation can place a crossing between samples, but a single-picosecond readout digit gives no assurance of accuracy at that level. For example, 5 mV RMS of input-referred noise and a local slope of 0.5 V/ns give about 0.005 ÷ 0.5 = 0.01 ns, or 10 ps RMS, of threshold-crossing noise on one channel. If both contributions are 10 ps RMS and independent, they combine to about 14 ps RMS. This is the noise contribution only. Residual fixture skew, range-dependent delay and changes in loading when probes swap can also affect the result. Tektronix delta-time specifications and the noise and slew-rate terms.

Report the mean and the distribution of matched edge pairs separately. The mean estimates fixed path delay while individual edges can still move. Suppose an application has a 300 ps upper limit and the measured mean is +250 ps. An established uncertainty range of ±70 ps for that result would cover +180 to +320 ps, which crosses the limit. Improve the measurement or apply the decision rule specified for the project. If the requirement instead applies to every edge or a defined percentile, acquire enough edge pairs to report the specified statistic. Fixed deskew leaves real edge-to-edge jitter in the measurement.

Show where the measurement begins and ends

Record the net and physical location for each test point. A point at a receiver pin, a point on the board side of a connector and a point at the end of a cable represent different paths. Any connector or cable lying within the defined path contributes real system delay. Save the common-edge captures before and after correction, the normal and swapped board captures, and the probe accessories, channel mapping, crossing rule, operating conditions and effective sample rate. When purchasing or quality receives a report that B arrives 250 ps late, those details show which paths and probes were involved. With one oscillator feeding both paths, the result describes relative arrival at the two selected points. The source's own jitter and output-to-output skew are separate specifications that require their own test points and conditions.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.