Measuring oscillator frequency before and after shock reveals lasting changes. A system that must keep communicating or sampling during the event can also be sensitive to microsecond interruptions. For that requirement, operate the specimen under its specified power and load and put acceleration, clock edges, and receiver status on one timeline. IEC 60068-2-27 describes prescribed shock methods. The applicable product plan sets pulse severity, mounting, operating state, and performance observation intervals.
Measure edge intervals alongside frequency
A 20 MHz clock has a 50 ns period. If adjacent valid rising edges during the event are 300 ns apart, six normal periods elapsed with five intermediate edges absent, assuming the waveform shows no valid crossing at the receiver threshold. A one-second total count would see five missing out of 20 million expected edges, equivalent to only 0.25 ppm. Uniform slight frequency error could produce the same count. Keep maximum edge intervals, high and low widths, and recovery times separately.
Define whether the event begins at a machine sync output or at an acceleration threshold. An unloaded or permitted engineering trial can establish their offset. Include pretrigger data of the stable state. If an acceleration trace clips, verify range and pulse shape under the approved test procedure before assessing performance during it.
Monitor the connections that move with the fixture
Give clock leads strain relief and check that probes and connectors stay secure. Capture clock near the source alongside its local supply and the downstream lock or error marker. A far-end dropout with an intact near-end waveform directs attention to the interconnect, receiver, and supply conditions. If both lose edges at the same time while supply stays within limits, investigate the device and attachment. Record axis, mounting, fastener torque, and fixture routing. Extra supports and pads can change the mechanical stimulus.
Try a reference clock that does not move with the setup to check for vibration-related faults in the acquisition chain. If separate instruments record electrical and mechanical data, give them a common trigger and estimate alignment error. Before formal testing, a known missing-edge stimulus can verify detection. Removing five edges from the example sequence should produce a reported 300 ns interval.
Specify allowable recovery and continuity separately
Suppose maximum edge spacing is 100 ns and the downstream lock signal must recover within 1 ms. An observed 300 ns gap violates the first item even if lock returns in 0.6 ms and before-and-after frequency passes. Other designs may allow interrupted clocks and automatic recovery. Use the actual plan for shock count, axis, polarity, and operating mode. Preserve an anomaly on one axis even if another axis looks quiet.
Save one event record per shock with pulse shape, orientation, electrical interruption, maximum interval, recovery point, and pre/post frequency. Mark acquisitions that missed data and repeat under reproducible conditions where required. Retain old before-and-after snapshots as evidence for those measurements and add synchronized records to show what happened during the event.
Specify acquisition capacity as well. A 6 ms shock interval, 1 ms before it, and 3 ms after it require at least 10 ms. At 1 GS/s this needs ten million raw samples per channel. Recheck rate and depth with acceleration, power, clock, and lock simultaneously enabled. If fast memory is insufficient, combine a slow record of the complete mechanical event with verified fast electrical captures and retain evidence of synchronization.
A filtered lock flag may recover later than the last abnormal edge. Video of a front-panel lamp generally gives only coarse timing. Record the actual status level with sample times and its debounce or hold behavior. Keep clock interval and system status as distinct measured quantities so recovery cannot be mistaken for uninterrupted operation.