Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Measurement and Acceptance

A 16 MHz clock edge rings. How much does the long probe ground lead contribute?

At a receiver pin, a 16 MHz clock shows several cycles of ringing after the rising edge, with a peak above the supply rail. Photograph the probe tip and long alligator-clip ground lead and save the first capture. If a short ground spring produces a different waveform at the same point, the first trace alone is a poor basis for judging input stress. Find out how much the measurement connection changes the trace, then see how much ringing you can reproduce on the board.

The clock repeats at 16 MHz, but its edge excites a faster probe resonance

The clock period is 62.5 ns. Each transition can still be fast enough to excite a resonant measurement loop formed by the probe tip, return path and input capacitance. A simple model puts the resonance near 1 / (2π√LC), with L the effective loop inductance and C the effective input capacitance. Suppose C is 10 pF and the long loop has 100 nH of inductance. The result is about 159 MHz, or a ringing period of 6.28 ns. Reducing L to 10 nH in the same model raises the result to about 503 MHz, or 1.99 ns. A shorter loop can push the resonance to a higher frequency, potentially above the usable bandwidth of the combined scope and probe.

These are calculations to illustrate the trend. Actual ringing also depends on driver impedance, probe capacitance, geometry and damping. Compare intervals between successive positive peaks after the same edge, using more than one interval where possible. If the long-lead pattern disappears with the short connection, the longer measurement loop contributed to what you saw. Lowering the bandwidth would also hide some genuine high-frequency content. Keep it fixed for this comparison. Tektronix probe primer with ground-lead comparisons, Keysight passive-probe LC resonance model.

Compare long, short and long again at the same point

  1. Record the original connection. Check how the scope and probe are grounded. A conventional benchtop scope's ground clip is usually connected to protective earth. Use it only at a reference node that can safely be grounded. For a floating measurement, use an appropriately rated differential or isolated probe. Compensate the passive probe as its manual specifies. Capture at the receiver with the voltage scale and sample rate visible, and photograph the hookup. Tektronix on earth-referenced scopes and floating measurements.
  2. Leave the tip on the same node and shorten its return. Fit a compatible ground spring or other short return. Use the same ground pad if it is within reach. If a nearby pad is needed, mark it in the photograph because its local potential may differ. Keep attenuation, DC coupling, vertical scale, bandwidth, timebase and trigger settings fixed. Take several captures and compare positive and negative peaks, peak spacing and settling time. Restore the long lead and check whether the original pattern returns while load and operating state stay the same.
  3. Check pickup and loading separately if needed. With both contact points fixed, change the orientation of the long loop slightly where it is safe to do so. If the peak changes with loop orientation, check for electromagnetic pickup from nearby switching nodes. Then try a low-input-capacitance probe with a short connection at the same point to check the remaining waveform. For a provisioned coaxial test port, establish its intended termination. Connecting a 50 Ω instrument input directly to a clock meant for a high-impedance CMOS receiver changes the load. Tektronix on return inductance and pickup, Keysight on probe accessories and loading.

Follow the clock path if ringing remains with a short return

Measure at the driver and receiver with short connections, then compare branch points and connectors if present. If the order of events in the same capture matters, verify relative probe delay with a common edge and check the extra loading of both probes. If the driver waveform is clean but the receiver still overshoots, inspect the trace impedance, stubs and termination. A hypothetical 100 mm trace with a propagation speed of 150 mm/ns has a round-trip delay of about 1.33 ns. Repeated steps near that spacing give you a length to investigate. Stackup and branching can change the actual path and delay.

On a single-load point-to-point line of known impedance, matching the driver impedance plus a series resistor to the trace impedance can give a starting source termination. For example, a 50 Ω line and a 25 Ω effective driver impedance suggest a 25 Ω series resistor. Check that starting estimate against the actual driver model, trace and load. Compare both edges, pulse widths and swing at the receiver under the same probing conditions. Branched nets, different terminations and voltage-dependent output impedance need their own models and checks. TI high-speed layout guide on reflections and source termination.

Check false clocking and input stress as separate questions

For function, inspect how often the waveform crosses the receiver's relevant threshold around one edge, at the actual supply and temperature. A Schmitt input has direction-dependent thresholds. If the data sheet gives only VIH(min) and VIL(max), use them to check guaranteed logic levels. Establish the actual switching point in the undefined region from device information or measurement. If an error counter is available, record the number of receiver events and errors during the test. For stress, check the specified input voltage, clamp current and any stated transient limits for that part. Probe-induced peaks can distort the stress measurement. A run with zero reported errors cannot establish that the input stayed within its stress limits. TI on interpreting logic input voltage and clamp-current ratings.

Give engineering or the supplier the long, short and restored-long captures on matching scales, along with the test point, local ground, probe accessory, bandwidth and effective sample rate. Add the short-return driver and receiver captures and the relevant electrical limits. The comparison shows whether a measurement fix is enough or whether the remaining waveform warrants work on the termination, layout or parts. If the peak appears with just one probing setup, state that condition when reporting it.