A board occasionally stops working when a peripheral powers up. The supply recovers and the processor's reset pin stays high, but some clock pulses are stretched or missing. Trace the oscillator supply at its pins and the point where the voltage supervisor takes its measurement. Establish when the clock left its guaranteed conditions, when valid pulses returned, and whether the supervisor could detect this short dip. Put both traces on one time axis to explain why the system can still be waiting after the rail recovers.
The oscillator and supervisor have separate limits
The oscillator data sheet defines the operating supply range. A dip outside it can modulate the clock, lose edges, or cause a restart depending on its depth and duration. Startup time is usually measured from a defined supply crossing to an output event. SiTime's oscillator glossary, for example, uses 90% of supply and the first output cycle. Its definition depends on those specific events. For a transient that does not pull the voltage to zero, check whether recovery is specified separately and reproduce it on the board.
A supervisor has its own threshold, hysteresis, detection time, and response to short transients. TI's TPS3808E timing diagram illustrates how the device can ignore a very short disturbance and assert reset once detection conditions are met. Once voltage recovers, it can hold reset for a programmed delay. The release delay does not promise instantaneous assertion at the threshold. Check for a bead, resistor, or switch between SENSE and the oscillator rail. A reading near the regulator and one at the oscillator are comparable only with the correct reference, point, and time.
A reset pin that appears unchanged has other explanations too. An open-drain reset with a separate pull-up rail depends on its pull-up, capacitance, and receiver threshold. Firmware may clear an internal brownout flag after boot. A long capture with insufficient sample density may miss a narrow reset. Save the failing condition and trigger from the supply disturbance before assigning the cause to the oscillator.
Worked timing example: Which guarantee fails first?
Assume a 1.8 V oscillator requires at least 1.71 V, and a hypothetical supervisor detects below 1.65 V. A peripheral pulls the oscillator rail to 1.66 V for 10 µs. A supervisor on the same node sees no threshold crossing, so reset need not assert. The oscillator is already out of specification. A supervisor upstream may see an even smaller drop. If the clock is abnormal then, investigate sensing position and thresholds. These example voltages and times cannot predict that a specific oscillator will stop.
Now assume the oscillator pin drops to 1.60 V for a very short interval. It crosses the example supervisor threshold, but assertion still depends on detection time at that depth. Reproduce a controlled sag under the real load. Mark when the oscillator leaves its operating range, when the sense input crosses the threshold, when reset reaches a valid low, and when the receiver sees a valid clock again. Exercise supported dip depths and widths. Keep clock loss without reset apart from reset that releases too early.
Use receiver criteria for when the restored clock is usable. The first few pulses may fail minimum widths, or a buffer may still be recovering. A board-level valid criterion can require several edges within frequency and pulse limits. Without an independent timebase, firmware can stop along with the clock it is meant to monitor. Use an independent monitor or a hardware status point where appropriate.
Use the traces to choose the correction
If practical, keep the dip within oscillator limits by addressing the load step, interconnect impedance, or bypass. If momentary clock loss is allowed, define downstream state during the loss and wait for the reference to recover before release. Increasing reset delay changes only release timing. It cannot help if the supervisor never asserted. For a new supervisor, review threshold tolerances, detection time versus overdrive, and output structure. Provide measurable thresholds and recovery criteria.
Before and after the change, repeat complete power cycles, load steps, and voltage boundary tests. Save local power, reset, and clock traces and state when recovery timing starts. For an intermittent fault, keep the peripheral-enable timing constant and see whether the event tracks the trough depth and duration.
Some builds feed the oscillator from an always-on branch. If the processor's supervisor remains on a different rail, include disturbances on both nodes in verification. Measure each trough against its local ground, document shared returns between instrument and circuit, and compare against the failed cycles at the receiver. That gives hardware and firmware teams a basis for repair without masking the issue behind a longer generic delay.