Why does changing clock recovery reduce TIE on the same 156.25 MHz waveform?

Analyze the same 156.25 MHz waveform twice, using the same rising edges and crossing threshold. One time interval error (TIE) trend slopes across the screen. After a clock recovery change, the result shows only a smaller variation. To account for the difference, find out where the matching reference timestamp came from for each measured edge. With TIE defined as measured time minus reference time, an early edge gives a negative value and a late edge gives a positive value. Moving the reference timestamps changes the difference even when the waveform and its crossings stay fixed. Tektronix TDSJIT3 algorithms for Clock TIE and Clock PLL TIE.

Keep the nominal period fixed to see the slope from a frequency offset

A 156.25 MHz clock has a nominal period of 6.4 ns. Suppose it runs 1 ppm fast, or 156.25 Hz above the fixed reference. Each actual period is then about 6.4 fs shorter. Start both clocks at the same phase. After 156,250 cycles, the reference is at 1 ms and the corresponding actual edge arrives about 1 ns early. The TIE trend starts at zero and falls about 1 ns per millisecond. That 1 ns is the accumulation of small errors across many periods. For a fixed-period reference, subtract successive TIE values to get the individual period errors, provided both timestamps represent adjacent cycles. Tektronix comparison of period jitter and accumulated TIE.

A fixed reference can come from a synthetic sequence at the nominal 6.4 ns period, with the input timed against the scope's own timebase. If a sufficiently stable independent clock is available, you can instead acquire both signals and define their rate relationship, initial alignment and corresponding edges. Check the measurement-chain delay and reference noise in that setup. State whether the reference timestamps were calculated from the nominal frequency or measured on a separate source. Check the timebase accuracy if absolute frequency offset matters.

If you fit a straight line to timestamps from the same capture, its slope estimates the average period and its intercept sets the reference origin. In the +1 ppm example, the fit absorbs the steady frequency difference, so the slope disappears from the residual. Save the fitted frequency, fit interval and residual. A very slow variation can look nearly linear over a short record, so the fit can absorb part of that as well. Compare trends from longer records and specified time windows to see what was removed.

A recovered reference can move with the input

A phase-locked loop (PLL) estimates the reference from the incoming signal. Slow input phase changes can move the recovered reference along with the input edges, reducing the measured difference. Disturbances much faster than the loop can track tend to remain in the residual. Around the bandwidth boundary, both magnitude and phase response matter. Practical clock recovery tools expose parameters such as loop type, order, bandwidth, damping and peaking. Check whether the stated bandwidth is defined for the transfer to the recovered clock or for the residual error response. Tektronix on clock recovery in measurement, Keysight FlexDCA loop bandwidth and tracking settings.

Use a locked first-order linear loop as an illustration. If the phase transfer to the reference is H = 1 / (1 + jr), with j the imaginary unit and r the modulation frequency divided by the loop bandwidth, the residual magnitude ratio is |1 − H| = r / √(1 + r²). Take a 10 kHz sinusoidal time deviation of 100 ps peak to peak. At a 10 kHz loop bandwidth, r = 1 and the residual is about 70.7 ps peak to peak. At 100 kHz loop bandwidth, r = 0.1 and the residual is about 10.0 ps peak to peak. These values apply to the single sinusoidal component under steady-state conditions. Actual instruments and receivers can have different loop responses and additional noise terms. Tektronix first-order PLL example and error transfer function.

Switch the clock model while keeping the edge file fixed

  1. Fix the input to the analysis. Save the continuous waveform or the extracted timestamps with their cycle numbers. Keep the analysis interval, sample rate, edge polarity, threshold and interpolation method fixed. Start with consecutive rising edges so the high-to-low duty-cycle asymmetry cannot enter the period comparison. If a gap is too long or a cycle has multiple crossings, inspect the waveform for a missing edge, noise or ringing and check the cycle numbering. A gap between segmented acquisitions cannot simply be treated as one clock period.
  2. Save the fixed-reference trend. Calculate TIE with the known nominal period or independent reference and record the slope and estimated frequency offset. Compare it with a constant period fitted to the same edges, and save the fitted frequency and edge count. If the curves mainly differ by a slope, check the frequency reference and the source of the average period. To check for periodic variation, compare the trend with its spectrum. A 10 kHz component repeats every 100 µs. A 2 ms interval covers about 20 cycles and gives a better view of whether it persists.
  3. Apply the prescribed recovery loop. Starting from the same data and valid interval, calculate PLL-referenced TIE and record the software version, loop order, bandwidth, peaking or damping. Check lock status and any startup transient. If you discard the settling interval, compare both methods over the same remaining data. Check edge pairing before attributing a jump in TIE to the source, especially if the loop lost lock or slipped a cycle.

Compare supplier samples using the same TIE definition

Label fixed-reference TIE, fit residual and receiver-model residual clearly. For oscillator frequency offset or drift, retain the fixed-reference trend and fitted frequency. For an interface jitter requirement, use the prescribed reference or receiver model. Keep capture length, edge count, bandwidth, filtering and trigger settings comparable across samples. Share the trends, raw waveform or timestamp file, and the interval over which peak-to-peak or RMS results were calculated. A peak-to-peak result is bounded by what happened during that record. A longer measurement can reveal larger extremes. When a recovery change attenuates a slow component, report the affected frequency range and loop settings so engineering or the supplier can investigate it. Tektronix examples of jitter histograms, trends and spectra.