A handheld device project requests a drop-resistant watch crystal, and the supplier quotes CM8V-T1A with “5000 g shock resistance.” The data sheet specifies a 5000 g peak acceleration, 0.3 ms duration, a half-sine pulse, and a corresponding frequency-change criterion. Those describe a controlled part-level shock test. Without product structure, impact direction, and mounting position, the number cannot be converted into a finished-product drop height.
Record the supplier's test and product acceptance on separate lines
For the crystal, record pulse shape, duration, device condition, and the frequency-change criterion. For the product, specify actual requirements such as enclosure state, impact face, power state, and whether clock interruption is permitted. Static frequencies within tolerance before and after the drop establish only those readings. If uninterrupted timekeeping through impact is required, use a test that captures transient events.
Have samples represent production assembly
Obtain the complete order code, load and accuracy options, and record trial board revision, soldering, and enclosure mounting. Drops in different directions can produce different PCB flexure and vibration. Keep traceability to each device position and orientation. Changing cushioning or enclosure supports calls for reassessing product-level results even if the crystal stays the same.
Use the component shock specification to screen candidates. Final release should follow the project's product-level test. If the customer requires a report, specify the conditions, sample lots, and conclusions it must cover rather than substituting one component parameter. Micro Crystal CM8V-T1A shock test conditions