ERP shows 14.318 MHz for a 14.31818 MHz crystal. How far did the target move?

The maintenance file says 14.31818 MHz. A CSV export shows 14.318, and one quote says 14.32. The numbers look similar, but purchasing needs the one the supplier will use for outgoing testing. Keep an exact integer in hertz if the purchasing display only allows three decimals. A rounded value used in a part search, tester, or ppm calculation becomes a different reference.

Decode the frequency code before reading the mark

ECS maps its abbreviated code 143 to 14.31818 MHz. Such digits can be a lookup key. Abracon's ABLS controlled drawing uses 14.31818 MHz in its ordering example. The ABLS-14.31818MHZ-K4T page lists that frequency, 18 pF, and ±30 ppm initial tolerance. One source uses a code table, and another includes the frequency in a complete ordering number. A top mark resembling 143 still does not establish the exact suffix or electrical option.

A purchasing description may be limited to two or three decimal places. Keep the short display for search and use an independent integer-hertz field and complete manufacturer number for computation and orders. Check the electronic PO, acknowledgement, attached part columns, and receiving method for round-trip accuracy. On a combined list of kHz RTC parts and MHz main clocks, carry a unit field. Specify the format read by the tester and exercise it on at least one non-integer value.

Recalculate from 14,318,180 Hz

14.31818 MHz is 14,318,180 Hz. The shortened 14.318 MHz equals 14,318,000 Hz, or 180 Hz lower, about −12.57 ppm against the original target. The 14.32 MHz entry is 14,320,000 Hz, or 1,820 Hz higher, about +127.11 ppm. This compares nominal centers. Ask the supplier which value controls the actual part. A spreadsheet can show fewer digits while retaining the exact value internally. Inspect the exported data to distinguish formatting from a changed value.

Suppose a repair requires ±10 ppm at room temperature about 14,318,180 Hz. The half-width is about 143.18 Hz and the theoretical interval is 14,318,036.82 to 14,318,323.18 Hz. The rounded center of 14,318,000 Hz falls outside. The Abracon example's ±30 ppm grade cannot provide the stated ±10 ppm repair guarantee by itself. Even if the nominal is exact, verify initial tolerance, temperature, and load before choosing a part.

Expose the target the test actually used

Give the supplier the exact frequency in both hertz and MHz and inspect against the complete ordering code. Retain raw frequency with sufficient resolution. Start the report with nominal and conditions and preserve both error in hertz and ppm. A result that just says off by 10 leaves its unit and center unknown. Check the computation once with a known input so the supplier and receiving station get the same sign and decision.

Existing systems can carry two checks, one that ties the label to the full order and one that confirms the acceptance method uses the approved center. Apply decimal formatting in the display only, and pass the exact value on the order and to the tester. If a reel in storage shows only 14.318, recover the original pack and complete code before deciding whether to retest.

For an older instrument that accepts a limited number of decimals, ask test engineering whether it can take a hertz input. If it cannot support this project, use an approved alternative and spot-check other parts fed by the same parameter export.

Investigate the document and shipment separately

For a quote of 14.32, get a written confirmation by exact manufacturer number and check the specification. If the label and number establish 14.31818 MHz and only the spreadsheet display rounded, correct the paperwork and inspect under the approved method. If the rounded value entered the test fixture, retain the first results and retest under the correct target. A shipment manufactured to another center is a part discrepancy, even when some windows overlap. Carry the integer field through the order and test to avoid losing precision on the next export.