A repair needs a through-hole 20 MHz crystal. The offers are ECS-200-S-4X and ECS-200-20-4X. The manufacturer's pages agree on geometry, operating range, ESR, and initial frequency tolerance. The S and 20 identify different frequency references. Confirm whether the order calls for series resonance or a 20 pF load before testing. A conforming unit can read outside the expected window in the wrong mode.
Put the two manufacturer entries side by side
ECS lists Series in the load field for ECS-200-S-4X and 20 pF for ECS-200-20-4X. Both pages list 20 MHz, 4X, 11.35 × 4.65 mm, ±30 ppm initial tolerance, ±50 ppm stability, −10 °C to +70 °C, and 30 Ω ESR. Those common fields confirm several similarities. Preserve the full code to capture the different frequency reference. S does not designate a generic shipping option, and 20 is not a redundant copy of the frequency.
If the board only provides lead pitch and a top mark, look for the original BOM, manufacturer label, and design records. Give engineering the controller type, load capacitors, and actual layout to verify the design tolerance and loading. Circuit topology and effective capacitance are more useful than package shape. Use the series table to shortlist parts and the full order code and design specification to approve one.
Use the equivalent circuit to explain the difference
ST's oscillator guide models crystal resonance with a motional branch and discusses effective load. In an ideal small-capacitance approximation, load resonance exceeds series resonance by a fractional amount of about C1 divided by twice the sum of C0 and CL. If C1 is 10 fF or 0.010 pF, C0 is 3 pF, and CL is 20 pF, the denominator is 46 pF. The offset is about 217 ppm, or 4.35 kHz around 20 MHz. These illustrative model values do not describe a measured ECS specimen. Use applicable parameters or measurements for an actual shift.
At 20 MHz, ±30 ppm corresponds to ±600 Hz. Two reports might both state 19,999,400 Hz through 20,000,600 Hz while using different resonances. The example shows that a load change could shift the result by several times that window. A report displaying only 20.000 MHz may not have enough resolution to inspect to ±600 Hz. An identical display does not establish the fixture load, reference point, or traceability.
Have the supplier and receiving measure the same reference
For the Series part, cite a series-frequency method. For the 20 pF part, write the effective load at the device, drive, temperature, and how cable and fixture parasitics are handled. A fixture may have one name and several selectable networks. Record the installed network and its calibration. Ask for the conditions before delivery and spot-check shared samples if results differ. Engineering can establish a separate board measurement and avoid mistaking probe loading for a part defect.
If the PO calls for 20 pF and the reel says S, put it on hold as a code discrepancy. If the material matches and receiving used the wrong load, preserve the report and retest under the correct conditions. The retest does not change what the first method did. If a redesign calls for the alternate reference, complete board qualification and update the BOM.
Maintain the fixture with two independent checks. Verify the counter timebase and range first, then effective load at the device. Traceability addresses frequency measurement. Load still depends on the fixture and how the part connects. Run a known retained device across stations to catch an incorrect setting. Confirm fixture drive and ambient conditions against the approved method. If an error is discovered after release, use the affected receiving IDs to identify which lots ran with that setting. Preserve the original results and the retest.
Put the reference next to the order code
Specify the full manufacturer number and list Series or 20 pF explicitly, with temperature range, ESR, and inspection method. Use a known sample to check the fixture setup at shift changes. If an old stock record merged the two, reconcile original labels and hold unknown units. The next operator needs to see what frequency was measured and at which defined resonance.
