Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Passive Crystals and Oscillator Circuits

An RFQ says “10 MHz, Series.” What goes in the load-capacitance field?

A legacy drawing says “10 MHz, Series,” and the purchasing system requires a numerical load capacitance. Entering 18 pF to submit the request would tell the supplier to calibrate to a finite load. Entering 0 pF would leave another misleading value. Identify the condition at which the drawing defines 10 MHz and carry that condition through the quotation and the receiving test. With different resonance definitions, two measurements on one crystal can differ by thousands of hertz.

Read “Series” in the context of the drawing

Some drawings use Series as a product-family heading. Others put series resonance in the frequency specification. Check its position against the maker's order code, drawing revision and frequency test conditions. Look for the original approval or receiving report, including the fixture setting. A top marking of 10.000 is a clue for tracing the part. If the original documentation is incomplete, keep the resonance condition open on the RFQ while circuit engineering confirms the intended configuration.

NDK defines series resonant frequency and the frequency with a load separately. In a simplified crystal model the motional inductance and capacitance form a series branch. The crystal itself also has shunt capacitance C0. At a finite external load, the characteristics of the crystal and the load both affect the operating frequency. NDK describes series resonance as the limit at infinite load capacitance. The infinity symbol names a mathematical or specification condition. Determine actual board components from the schematic and the approved assembly. Also specify the mechanical vibration mode, such as fundamental or the applicable overtone. NDK glossary, resonance, load capacitance and overtone order.

Estimate the difference on the same 10 MHz crystal

Suppose a crystal has a series resonant frequency fs of exactly 10,000,000 Hz. For this calculation, assume its motional capacitance C1 is 10 fF, or 0.010 pF, and its shunt capacitance C0 is 3 pF. Epson's matching note gives the approximation (fL − fs) ÷ fs ≈ C1 ÷ [2 × (C0 + CL)]. Put all capacitances in the same unit. This estimate concerns a small shift on one vibration mode under the model assumptions.

  • At 18 pF, the denominator is 2 × (3 + 18) = 42 pF. The ratio 0.010 ÷ 42 is about 238 ppm. The predicted loaded frequency is approximately 10,002,381 Hz.
  • At 12 pF on the same crystal, the denominator is 30 pF. The predicted shift is about 333 ppm and the loaded frequency is approximately 10,003,333 Hz. The two loaded predictions differ by about 952 Hz.
  • If the vendor instead calibrates to 10,000,000 Hz at 18 pF, reverse the first approximation using 10,000,000 ÷ (1 + 0.010 ÷ 42). With the same assumed equivalent capacitances, the target series resonance would be about 9,997,620 Hz.

These figures illustrate how the specified measurement condition changes the result. An actual part can have different motional and shunt capacitances. Use the manufacturer's equivalent circuit or pull curve when a numerical estimate is needed, then verify the result using the agreed fixture. Epson technical note on frequency matching between the crystal and oscillator circuit.

Use the ordered condition for the acceptance window

Suppose the order calls for 10 MHz ±20 ppm at an agreed temperature and drive level in an 18 pF fixture. At 10 MHz, ±20 ppm is ±200 Hz. The resulting interval is 9,999,800 to 10,000,200 Hz. A reading of 10,000,050 Hz in that fixture is +5 ppm. Under the same equivalent-circuit assumptions, the corresponding series resonant reading would be about 9,997,670 Hz. Label and retain each reading under its own test definition. For contractual acceptance, apply the agreed rule to the result at 18 pF.

Account for measurement uncertainty close to a limit. Suppose the loaded reading is +190 Hz and the lab has evaluated an expanded uncertainty of 25 Hz. The interval from +165 to +215 Hz crosses the +200 Hz limit. Check timebase calibration, fixture compensation, test drive and temperature. Use the agreed decision rule to determine whether the unit needs retesting or a separate disposition. Keep that rule in the same record as the result.

Board-level measurement answers a different question from incoming inspection. The latter checks the supplied crystal against the order. On the board, verify effective load, startup and the final clock. If the crystal passes in the fixture while the board runs fast, check board parasitics, configured internal capacitance and the reference source selected by firmware. Any load adjustment should have before-and-after measurements and a repeat startup check at the required conditions.

Record the condition in the BOM and the test report

A series-resonant item can be written “10.000000 MHz, fundamental, calibrated at series resonance,” followed by the approved part number, drawing revision, tolerance, reference temperature and drive condition. A load-resonant item can read “10.000000 MHz, fundamental, calibrated at CL = 18 pF,” with its own approved specifications. Confirm the case, pinout, ESR and permitted drive for either part. Give the purchasing system a controlled series-resonance value or a suitable not-applicable status linked to the technical attachment. When the supplier's reply, incoming report and assembly record all identify the same frequency definition, the next substitution can be reviewed against a known baseline.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.