A board uses the CS2000-CP to generate a 24.576 MHz clock. The old design has a 25 MHz passive crystal, while the next revision uses a 50 MHz active oscillator. Changing the input divider from two to four does keep the internal time base at 12.5 MHz. The static synthesis ratio, however, is expressed relative to the external frequency. If it is left unchanged, the output target doubles. It helps to calculate the acceptable reference input and the desired output separately. Purchasing can then specify the right part, and engineering can check which configuration value was missed.
Check the reference path first
The Cirrus Logic data sheet lists separate limits for the external reference and internal system clock. With a 25 MHz passive crystal, dividing by two gives 12.5 MHz. With a 50 MHz active oscillator as the reference, the external clock column calls for the divide-by-four range, again giving 12.5 MHz. Both are within the specified 8–14 MHz internal system-clock range. Leaving the divider at two with a 50 MHz input would give 25 MHz internally. An accurate 50 MHz reading at the external input would not by itself establish that the configuration is valid.
The active oscillator has its own supply. Check the module’s swing, duty cycle, and logic levels against the CS2000-CP external reference requirements. The data sheet also specifies how to handle XTO when an external reference drives XTI/REF_CLK. Verify the schematic and installed components, particularly any passive-crystal loading parts still present on the original revision. When both board versions run on the same assembly line, tie each oscillator type and its circuit options to the exact assembly revision.
Divide the output by the actual external frequency
Section 5.3.1 describes how the device accounts for the reference divider in static synthesis mode. RUD expresses the desired output-to-external-input frequency ratio. Assuming the unity ratio modifier, the ideal value for a 25 MHz crystal and 24.576 MHz output is 24.576/25, or 0.98304. For the 50 MHz active oscillator, the ratio is 24.576/50, or 0.49152. Reusing 0.98304 at a nominal 50 MHz input sets a 49.152 MHz target. If the board produces close to twice the intended output, read back this field and confirm the selected ratio slot, active input, and any downstream division.
In static mode, this ratio uses unsigned 12.20 fixed-point encoding. Rounding to the nearest integer gives 1,030,792, or 0x000FBA88, for 0.98304 multiplied by 1,048,576. The new ratio yields 515,396, or 0x0007DD44. The encoded values happen to be exactly two to one, and either correctly matched setup has a nominal output of about 24,575,996.4 Hz. The roughly 3.6 Hz shortfall in this calculation comes from rounding. The actual error also includes the reference tolerance and measurement uncertainty. Keep the ratio equation and final register bytes with the firmware review so the selected slot can be verified.
For example, 20 ppm of reference-frequency error corresponds to about 491.52 Hz at the target output. This is the nominal output multiplied by 20 parts per million, before allowing for jitter or instrument error. It also explains why a second 50 MHz oscillator with a different temperature-stability option needs its own frequency budget. Record the ratio-rounding and source errors separately to see which part is worth improving.
Check which mode was active during measurement
In Hybrid PLL mode, the device derives the output frequency relationship from CLK_IN. With both a timing reference and a synchronization input, determine whether the system is using manual static synthesis, manual Hybrid PLL, or automatic selection based on the presence of CLK_IN. The two hex examples above are for static synthesis. Save the selected fields, active ratio slot, and whether CLK_IN was present during the test. Otherwise a board may pass with no sync input on the bench and then use a different ratio in the system.
Use a known supply and temperature for both measurements. On the 25 MHz passive-crystal board, avoid placing a high-capacitance probe on the oscillator node. Start with the configured output and lock status, then use a characterized low-loading point if needed. On the 50 MHz active-oscillator board, check the module’s output under the permitted measurement load before inspecting the synthesized clock. A single steady-frequency reading after initialization says little about startup, reset, or a later change of reference. Capture those events separately if they occur in normal use.
Tie the oscillator and firmware versions together for purchasing
For the 25 MHz passive crystal, keep the complete ordering code, load capacitance, rated drive, ESR, and matching network. The 50 MHz active oscillator needs its own supply range, output type, input threshold check, frequency budget, and enable behavior. Tie both parts to the correct assembly, firmware, and CS2000-CP configuration. The acceptance record should include the external frequency, input divider, ratio equation, register readback, and measured frequency after lock. If the output is close to double, start with the ratio and active input mode. If no clock appears, first verify the input range, divider, source startup, and input circuit.
Use the earlier firmware and assembly as a control and qualify the new pair at the same supply and temperature, with the same sync input state. If the wrong firmware can be loaded on the line, check the board identification against the firmware configuration without running an intentionally out-of-range clock. For a later frequency change, check the appropriate input band first and then recalculate the static ratio from the external frequency.