A board with the three-lead Murata CSTLS4M00G53-A0 inserted backwards may still boot. The ground lead stays in the middle, while the two outer leads trade places. For this nominal 4.000 MHz resonator, Murata’s individual specification JGC40-5019 gives an initial frequency tolerance of ±0.50% in the specified orientation and ±0.60% when pins 1 and 3 are interchanged. On a returned unit or a production build, check the part against the assembly drawing and use the board’s frequency requirements to decide whether it needs rework. Confirm that the host actually selected this clock source, especially on products that can fall back to an internal clock.
Read the marked face and trace all three leads
Hold the resonator so its marking faces you and the leads point down. The package drawing in Section 6 of JGC40-5019 labels the pins 3, 2 and 1 from left to right. Following Murata’s CERALOCK wiring guide, connect pin 1 to the host’s XIN, pin 2 to ground and pin 3 to XOUT. A 180-degree turn on the board swaps the outer leads while leaving the center lead in the ground hole. All three leads can still line up with the holes, so check the marked face and the hole numbers on the first build. Verify the drawing’s viewing direction when checking from the solder side. Murata’s package and terminal drawing, Section 6 and Murata’s CERALOCK orientation guide.
The resonator contains two load capacitor branches. C1 connects pins 1 and 2, and C2 connects pins 3 and 2. The specification gives 15 pF ±20% for each capacitor as a reference value measured at 1 MHz. The two actual capacitances in one device can differ. Reversing the part moves each capacitor to the other side of an oscillator whose input and output circuits and traces can also present different loads. Both orientations can therefore start while giving different frequency readings. Murata individual specification, Section 5 and Murata’s explanation of frequency shift after reversal.
Consider a hypothetical pair of 14 pF and 16 pF capacitors for C1 and C2. Suppose the board and host add fixed parasitic capacitances to ground of 3 pF at XIN and 7 pF at XOUT. The branch totals are 17 pF and 23 pF in the specified orientation, or 19 pF and 21 pF when reversed. In a model of only those two capacitor branches, their series equivalent between the oscillator nodes goes from 9.775 pF to 9.975 pF. This calculation shows how swapping the capacitors can change the load. The direction and size of the resulting frequency shift depend on the resonator and the host circuit and should be measured on the actual board.
The 4 kHz difference applies to the tolerance limits
At nominal 4.000 MHz, ±0.50% equals ±5,000 ppm or ±20 kHz. That gives an initial range of 3.980–4.020 MHz. The ±0.60% figure equals ±6,000 ppm or ±24 kHz, giving 3.976–4.024 MHz. The range extends by 4 kHz at each end. To find how far one device moves when it is reversed, compare its frequency under equivalent circuit conditions. Murata’s general mounting FAQ also cautions that tight-tolerance parts trimmed on a customer PCB may miss their original target when reversed. Check the individual specification when using another series or part. Murata JGC40-5019 initial limits and reversal footnote and Murata’s guidance on reversed mounting for tight-tolerance parts.
Suppose a product allocates ±0.55% of room-temperature initial error to this 4 MHz reference, equivalent to ±22 kHz. The normal-orientation component limit of ±20 kHz fits that allowance, while the reversed limit of ±24 kHz exceeds it. A reversed sample that passes at room temperature still leaves the wider production limit to account for. If the clock drives a timer or serial link, enter temperature and aging separately and account for any divider error and the clock at the far end of the link. If the old board uses a quartz crystal specified in tens of ppm, put both parts into the same units and check the margin before comparing cost and fit.
For this G53 part, the temperature shift is at most ±0.20% from −20 to +80 °C, relative to its initial frequency at +25 °C. The long-term change limit is also ±0.20% relative to the initial value under the specified condition of ten years at +25 °C and 60% relative humidity. The CSTLS_G series page lists a 47 pF version with a different temperature shift of −0.40% to +0.20%. If the only available code is “CSTLS4M00,” obtain the suffix and the individual specification before choosing a tolerance. Murata individual specification, Section 5 and Murata CSTLS_G series data.
Match incoming inspection and board measurements to their conditions
Section 10 of the individual specification shows Murata’s circuit for measuring initial frequency. Figure 1 uses a specified unbuffered inverter circuit, a 5 ± 0.1 V supply and an output for the frequency counter. The standard environment is +25 ± 5 °C and 20% to 85% relative humidity. If incoming inspection uses Murata’s limits, agree on the fixture, orientation and conditions. The assembled product’s own chip and PCB loading can shift its frequency. If a measured board falls outside its limit, record the fitted orientation, supply, temperature, clock path and measurement point so the team can investigate whether the component or the board circuit is responsible. Murata individual specification, Section 10 and Figure 1.
When an orientation comparison is needed, fit new parts from the same lot to boards of the same revision, with one group in each orientation. Record frequency, startup time and critical functions at the supply and temperature limits of the product. Use several samples to observe variation among parts and boards, and apply the same conditions to both groups. Prefer a buffered clock output with a verified source, then account for any division when converting back to 4 MHz. If probing an oscillator pin directly, account for the probe’s input capacitance. A useful rework record shows the old part orientation, the replacement orientation and the frequency measurement conditions.
Put the full part number on the parts bin and work order
JGC40-5019 covers the taped CSTLS4M00G53-A0 and the bulk CSTLS4M00G53-B0. They share electrical requirements, with separate drawings and packaging instructions. Choose the code for the intended assembly station. For automated insertion, check the tape feed direction and which way the marking faces on the first piece. For repair stock, put the exact manufacturer part number and an orientation drawing on the bin and the work order. When old stock includes quartz crystals or other three-lead ceramic parts at 4 MHz, confirm the exact code and pinout before issuing parts. Murata individual specification, Sections 1 and 6 through 9.
Confirm supply separately. Murata lists March 31, 2028 as the planned discontinuation date for the 3.40–10.00 MHz CSTLS_G series. For boards still in production or service, ask for lot information, available quantity and lead time for the full code. For a proposed substitute, compare through-hole versus surface-mount construction, pinout, built-in capacitance and frequency limits, then qualify it on the intended board. When an assembled lot contains reversed parts, trace the orientations and use the product’s acceptance criteria to decide which boards need retesting or rework. Record that decision in the assembly instructions. Murata timing device discontinuation information.