A request for 'TSX2016' may describe a 2.0 × 1.6 mm quartz part or a crystal with a temperature sensor. Obtain the original full part number and drawing. For thermistor-equipped designs, Kyocera's CT2016DB shows a distinction worth checking: initial tolerance is specified near 25 °C, while temperature characteristics are referenced to the frequency at 32 °C.
Keep the thermistor and frequency reference conditions separate
The CT2016DB lists 19.2 and 38.4 MHz, fundamental mode, and 7 pF load. The thermistor is 100 kΩ at 25 °C, ±1%, with a B constant of 4250 K, ±1%, specified over 25 to 50 °C. These values describe its sensing branch. The frequency table separately specifies initial tolerance near 25 °C and change relative to the frequency at 32 °C. Using one reference for both can offset the compensation table.
For sample tests, record ambient temperature, sensor-pin reading, temperature near the crystal, and measured frequency separately. Collect data at both references, then calculate correction using the firmware's reference convention. Room-temperature resistance alone cannot establish the crystal's thermal curve. The sensing branch requires the host circuit and does not by itself provide the output of a TCXO.
Specify frequency, the functions of the four terminals, thermistor characteristics, and the temperature reference in the RFQ. Confirm the requirement if the customer actually needs a passive crystal with two electrical terminals. CT2016DB illustrates which fields to compare without establishing equivalence to TSX2016.Kyocera CT2016DB electrical and thermistor characteristics