During repair of a cylindrical 32.768 kHz crystal, moving solder close to the can to shorten the leads can violate handling requirements. For applicable leaded products, Seiko Instruments requires soldering on the lead more than 1.0 mm from the glass seal. This describes the solder location relative to the seal and is separate from body diameter, insertion depth or requirements from other manufacturers.
Identify three physical points on the drawing
Mark the can end, lead feedthrough and actual wetted solder region in the assembly photo. Use a side view or cross section if only the projecting lead tip is visible. The straight lead length at a bend and the solder-to-seal distance are separate measurements. Pulling the lead to reposition solder can transfer force into the seal.
Use a process-validation board and follow the exact model's soldering time, temperature and force limits. Save before-and-after frequency and startup data. If a seal cracks, a lead loosens or the process exceeds its limits, retain evidence and consult the manufacturer through quality. Successful timekeeping immediately after repair does not establish seal life.
For repair purchasing, obtain lead form, can length, drawing and soldering limits along with frequency and load. Check the installed distance from pad to support. If there is insufficient room, evaluate another package or layout first. Do not generalize a one-millimeter drawing detail to a different seal design.Seiko Instruments Quartz Crystal Unit Handling Precautions