A system needs a test tone at a noninteger megahertz frequency. It can use a custom source or a DDS driven by an existing reference. With DDS, software control alone does not mean every frequency is realizable. A finite phase accumulator places outputs on a discrete grid. Calculate the nearest point before assessing reference accuracy and spectral quality.
Calculate the frequency step from the internal system clock
In normal single-tone mode, the AD9910 uses a 32-bit frequency tuning word. At an actual internal system clock of 1 GHz, one least-significant-bit step is about 0.23283 Hz. Calculate the word as target frequency multiplied by 2³² and divided by the internal system clock, rounded to the nearest integer. If the external oscillator is multiplied, use the effective multiplied clock and confirm lock. Using the external oscillator's label directly selects the wrong frequency.
Under these assumptions, rounding contributes at most about half a step, or 0.11642 Hz. If the application allows only 0.05 Hz error, calculate the rounded word for that target and work back to the actual output rather than relying on the half-step bound. Relative system-clock error also carries to the DDS output. Fine digital steps improve programmability while absolute reference accuracy needs independent verification.
For prototype acceptance, save the target, written hexadecimal word, internal clock, and reconstructed frequency before measuring the filtered output against an independent reference. Check the reconstruction filter and in-band spurs for the application. If a downstream module needs a digital clock with specified levels, duty cycle, and startup timing, verify the shaped output against those requirements too.ADI AD9910 data sheet: frequency tuning word