A channel report may list only Sdd21, the forward transmission from differential input to differential output. Connector or trace asymmetry can convert some of the differential energy to common mode while insertion loss remains acceptable. A four-port VNA separates these effects on the passive path. Plot conversion over the edge bandwidth, especially when the carrier looks fine but receiver edges or emissions are problematic.
A 30 ps difference matters more at higher frequencies
Consider two lossless single-ended paths driven by equal and opposite waves. If one path is delayed by Δt, the ratio of outgoing common-mode to differential-mode wave magnitudes is |tan(πfΔt)| with modes formed from equally referenced single-ended waves. For Δt = 30 ps, the ratio is about 0.0147 or −36.6 dB at 156.25 MHz and 0.0945 or −20.5 dB at 1 GHz. Scd21 relates outgoing common mode to incident differential mode, which is |sin(πfΔt)| in this model. Sdd21 has magnitude |cos(πfΔt)|. These conversion ratios are close when the delay is small but are different definitions.
At 1 GHz the ideal Sdd21 loss is only about 0.039 dB. Connectors, antipads, and return-path discontinuities can also convert modes, so verify fixture and amplitude balance before attributing an observed response to a particular delay. A clean point at 156.25 MHz also leaves open the possibility of a conversion peak at higher frequency.
Map four physical ports into two balanced ports
Connect each positive and negative conductor at both ends to its own VNA port. Record pairing, polarity, and direction. In this VNA notation the first mode index is output and the second is input. Scd21 is differential-to-common forward conversion. Sdc21 is common-to-differential. A natural pairing of 50 Ω ports uses 100 Ω differential and 25 Ω common-mode reference impedances. Record any renormalization because parameters depend on the reference definitions.
Measure the passive channel or a representative coupon with active drivers and receivers disconnected. Verify actual bias and loading separately in time-domain operation. Calibrate each cable to the required plane and measure a symmetric through to estimate residual conversion. If that through reads about −26 dB at 1 GHz, a device reading of −28 dB is difficult to interpret. Check remating and cable movement on the through as needed before judging product.
Locate the contribution and document the limits
Keep the port layout and reference plane fixed while comparing boards or structures. Measure a path without an adapter, a connector coupon, and the complete path where available. A conversion increase limited to one adapter justifies a separate check of that part. Identify the direction and mode definition on every trace. Confirm actual clock amplitude, bias, and transients at the receiver separately under the operating termination.
If an example requirement calls for Scd21 below −30 dB from 100 MHz to 1 GHz, an acceptable Sdd21 trace does not settle it. A conversion peak of −23 dB, with a much lower verified fixture residual, warrants investigation of the path. Confirm the frequency range covers the actual edges, especially after substituting a faster source. Preserve raw single-ended parameters, converted traces, calibration state, port pairing, and the through check for reproducible analysis.
Magnitude alone does not identify the affected leg. Swapping one pair’s polarity can change phase signs, and incorrect port mapping can even reverse the interpreted direction. Check polarity on a symmetric through and a known delay imbalance before testing the channel. If a conversion peak follows a moved VNA cable, repeat fixture checks before calling it a board defect.
Keep a separate single-ended connection check. A partly mated conductor can worsen both differential insertion loss and conversion over a band. Compare individual leg amplitudes and delays before trying to infer location from one Scd21 trace. Once connections repeat, use intermediate coupons to localize the cause.
