Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

Which current limit applies to the ECS-2100AX-500 50 MHz active oscillator?

An older control board needs a replacement for its 5 V clock, and engineering proposes the ECS-2100AX-500. The original manufacturer lists frequency, supply, and stability for this 50 MHz active oscillator. The family data sheet also puts exactly 50.000 MHz at the end of one current row and at the start of the next. One maximum is 46 mA and the other is 77 mA. A board with only 60 mA available at the oscillator needs a written answer before purchase approval. A few bench readings in the 30 mA range can help evaluate a circuit. Ask the supplier for the manufacturer interpretation of both rows and their scope at exactly 50 MHz before applying a production limit.

Both rows include 50 MHz, so calculate the board margin

The ECS-2100X family table lists 33 mA typical and 46 mA maximum at 25.000 to 50.000 MHz. Its 50.000 to 80.000 MHz row gives 45 mA typical and 77 mA maximum. The manufacturer page for the ECS-2100AX-500 identifies 5 V, 50 MHz, ±100 ppm, and operation from 0 to +70 °C. The product parameters on that page give no exact-frequency current maximum. Avoid filling the approval record with a typical value or assuming that the first row applies because of table order. Ask for an applicable maximum, measured supply voltage, load, temperature, coverage of startup, and the revision of the specification used for the answer.

Until that answer arrives, the higher value can inform planning for the 50 MHz active oscillator. The family supply maximum is 5.25 V. Multiplying by 46 mA and 77 mA gives 241.5 mW and 404.25 mW respectively. These are budget figures formed from the specified voltage maximum and respective current limits, rather than measured thermal dissipation. A 60 mA allocation gives 14 mA of margin under one interpretation and a 17 mA shortfall under the other. For a shared supply, subtract demand from other loads to verify that the 60 mA allocation is actually available. If the higher figure fits, prototypes can proceed while the purchase record awaits confirmation. If the board depends on the 46 mA limit, establish it before approving volume.

Test the load that the socket actually sees

The family table lists up to ten TTL loads and a 50 pF HCMOS load entry at frequencies below 80 MHz. An old drawing marked TTL clock can still have additions such as capacitive inputs, test points, or a plug-in cable. Ask engineering to identify the applicable load and describe the receivers and cables used for qualification. Test on a known fixture and repeat on the production socket. Include probe capacitance in the fixture load so that measurement does not create a current discrepancy. Record several steady readings after startup and capture turn-on separately with a suitable current monitor or shunt. A current-limited supply can interrupt the waveform and leave a deceptively low average reading.

For a lot that repeatedly restarts on the bench, record oscillator pin voltage, supply current, and output together. If the socket first drops below the 4.75 V supply minimum and the clock stops afterward, investigate the board supply. Repeat with the candidate on a compliant fixture and use the same load for a known approved part. If only the candidate draws more current, apply the written 50 MHz limit when deciding whether to raise a supplier issue. If both parts cause droop, inspect the common supply and fixture contact. If removing a series shunt restores operation, retain the original shunt voltage drop at transient current so the difference between test rounds stays explainable.

Use the sample plan to distinguish the first shipment from later lots. For a small repair allocation, ask the supplier to identify the sample lot, measurement conditions, and specification proposed for future deliveries. A supplier that offers only a sample curve may support an evaluation limited to that lot. The earlier measurement remains a useful comparison when another lot arrives, but the approved conditions determine acceptance. The purchase record can also say whether the board already has an approved option to increase its current allocation. Once the answer arrives, procurement can tell whether updating the part record is enough or whether material release depends on a hardware change.

Verify the pinout and intended use before ordering a repair substitution

ECS also lists the similarly named ECS-100AX-500 at 5 V and 50 MHz in a full-size through-hole family. Its drawing gives pin 7 for case ground, pin 8 for output, and pin 14 for supply. The half-size ECS-2100X drawing places terminals at positions 1, 4, 5, and 8. If a contractor picks the wrong family by the common 500 suffix, each can read 50 MHz in its own fixture while requiring a different socket and pinout. The ECS-100X document also marks the family as not recommended for new designs. A new board should use the manufacturer document and status relevant to its intended configuration. A repair allocation needs the exact board and approved device rather than a broad catalog equivalency.

The purchase attachment can carry the complete code, PCB revision, 5 V supply, output load, and applicable 50 MHz current maximum. Receiving verifies label and physical form, and engineering records current, supply, frequency, and startup using both a fixture and a representative board. Matching labels and frequency readings can support sample work while an order with a hard 60 mA allocation waits for a confirmed limit. If repair approves a different item, identify its board and current conditions separately. The next work order at the 50 MHz boundary can then use the original manufacturer clarification directly.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.