Engineering adds a 40 MHz automotive crystal from the ECS 37QZ family to an older bill of materials. A supplier sends a family PDF whose second-page list of developed frequencies omits 40 MHz, and purchasing returns the quote. Another supplier cites an exact manufacturer part page that specifies 40 MHz. Both documents can coexist. An earlier family table may not include later published configurations, and an exact page cannot establish every custom option. Match the requirement to the order number and ask the manufacturer which controlled document applies. A standard-frequency list does not establish supply status.
Compare electrical conditions for two exact part numbers
ECS lists ECS-400-8-37QZ-RES-TR and ECS-400-10-37QZ-RES-TR. Both 40 MHz crystals have a nominal 2.0 × 1.6 mm package, ±15 ppm initial tolerance, ±50 ppm stability, −40 to +125 °C operation, and 70 Ω in the ESR field. Both are listed as AEC-Q200. The capacitive load is 8 pF for one and 10 pF for the other. The family PDF’s developed-frequency table includes 16, 18.08, 19.6875, 24, 25, 26, and 32 MHz. It omits 40 MHz, while the same PDF’s electrical range includes it and gives a 70 Ω limit for 40 to 60 MHz. That discrepancy merits clarification and says nothing about stock or an approved supply commitment.
Check the option letters as well. The family PDF’s ordering example uses ADS. A corresponds to 25 ppm initial tolerance, D to 100 ppm stability, and S to the extended temperature range. The two 40 MHz numbers use RES. In the chart, R and E correspond to 15 and 50 ppm, while S retains the extended-temperature meaning. The A and DS electrical example on the first page does not set the limits for an RES quote. When a supplier offers a new revision or customer code, document its initial tolerance, temperature stability, operating range, and applicable specification revision.
Convert 8 pF versus 10 pF into board configurations
Suppose a symmetric load model includes 2 pF of stray capacitance. Two 12 pF capacitors combine to 6 pF in series, for an effective 8 pF. Two 16 pF capacitors yield 8 pF in series and 10 pF total. If the board actually has 3 pF of stray capacitance, the first pair produces about 9 pF total. The specified 8 pF is a starting point for qualification. Check the real board load and resulting frequency. To schedule samples, two boards types with two capacitor versions each and three specimens per configuration would require twelve builds. Record actual crystal and capacitor part numbers on each.
At 40 MHz, 15 ppm is 600 Hz and 50 ppm is 2,000 Hz. If the manufacturer confirms that the 50 ppm term is change from the reference temperature, a worst-direction sum gives 2,600 Hz before board load error and aging. An illustrative allocation of 2,800 Hz for initial and temperature terms leaves 200 Hz under those conditions. Before comparing samples measured at the same temperature, establish whether the fixture presents 8 or 10 pF. Testing both in a 10 pF fixture exposes the two crystals to different offsets from their respective loads and cannot rank their manufacturing quality.
Turn the document discrepancy into a receiving check
Specify the full manufacturer code and load field and obtain the applicable specification and test method. At receipt, match the reel label, purchase lot, and specification revision. If the family PDF omits the frequency, ask for an exact manufacturer page or a documented manufacturer cross-reference. For a load change, have quality verify the distinct incoming specifications and engineering repeat frequency, startup, and thermal testing on the approved assembly. A board can start at room temperature with an incorrect load. Record the crystal and both capacitor versions against the first-article board.
Ask the supplier to identify the relationships between the developed frequencies, general electrical table, and lot-specific measurements in the approval. For example, a previous 24 MHz order may have used 100 Ω from the 20 to 25.999 MHz band. Applying it to 40 MHz adds 30 Ω to the permitted resistance. Suppose the shipment measures 78 Ω with 3 Ω uncertainty and the agreed limit is 70 Ω. The entire 75–81 Ω interval exceeds the limit. Investigate it under the agreed plan. The 100 Ω figure for another frequency band cannot release it. If the supplier gives a resistance without a method, first check fixture, temperature, and drive. This evidence is also useful when the inspection program retains an old grade. Give the test engineer the exact specification row and limit, then verify the change with an agreed sample and borderline data so the old and new outcomes remain traceable.
Give a 20 MHz crystal from the same family its own approval line. ECS-200-10-37QZ-AES-TR lists ±25 ppm initial and 100 Ω ESR, which differ from the 40 MHz values. A supplier can legitimately send shared family documents for multiple orders. Receiving still needs to verify that each box matches its ordered frequency and load. Keep the full number with the reel and fixture in the test report so procurement can ask for evidence, reject a mismatch, or release approved material.