Two ECS 48 MHz passive crystals are rated to 125°C. Can the ES and DS suffixes share a material record?

A supplier offers the ECS-480-10-36Q-ES-TR and ECS-480-10-36Q-DS-TR as 48 MHz passive crystals. Frequency, package, rated load and operating range match. Incoming samples may even measure close to each other at room temperature. The stability character in the ordering code still affects acceptance. ECS lists ±50 ppm temperature stability for ES and ±100 ppm for DS. Both can operate up to 125°C under the limits specified for their own stability grade.

Compare the full ordering code and the specifications behind it

ECS lists both parts as 2.50 × 2.00 mm, 48 MHz, 10 pF, ±30 ppm initial tolerance and −40 to +125°C, with 40 Ω ESR. In the family ordering guide, E is ±50 ppm stability, D is ±100 ppm and S is the −40 to +125°C range. TR indicates tape and reel. A short description such as “480-10-36Q high temperature, reel” drops the stability field. Ask the supplier to put the complete part number and document revision on the quote, sample label and production order. Check that the outer box and inner reel labels map to the same lot.

The family data sheet also lists ±5 ppm first-year aging at +25°C ±3°C, along with oscillation mode, drive limit and maximum ESR for the 48 MHz frequency band. Save the conditions for these fields with the approval. If room-temperature aging data need to support long-term high-temperature use, check the service interval and test conditions. The first room-temperature year cannot establish the high-temperature lifetime. Likewise, a shared 40 Ω maximum does not imply equal resistance distributions. Incoming sample data and cold startup measurements can check that the project has adequate margin.

Keep room-temperature and temperature effects separate in the budget

Suppose a project allows ±110 ppm for this reference over a stated service interval. Assume that engineering sets aside ±10 ppm for board loading and has established that the cited first-year room-temperature aging is applicable as a ±5 ppm term in the example. Summing the worst-case magnitudes for ES gives 30 + 50 + 5 + 10 = 95 ppm. At 48 MHz, 1 ppm equals 48 Hz. The budget is therefore ±4,560 Hz, leaving 15 ppm or 720 Hz. DS comes to 30 + 100 + 5 + 10 = 145 ppm, or ±6,960 Hz, which is 35 ppm over the limit. These are example budgets. For a real project, confirm the range, method and time represented by each item.

A factory might trim both versions to a few ppm at 25°C and assume that the existing calibration can absorb the difference. Fixed room-temperature calibration primarily removes the assembled board’s error under that condition. Without compensation across the range, the specified temperature drift remains. Consider a calibration residual of ±5 ppm plus the DS part's ±100 ppm temperature stability and an independent ±10 ppm loading budget. This already totals ±115 ppm before aging. Revising the budget requires a documented calibration process that can be reproduced in production and validated across operating conditions.

Verify the stability field in a chamber

Both parts are 48 MHz passive crystals. Compare their drift on the same board revision, capacitor values and measurement method. Record room-temperature frequency first and measure at the engineering test points after the local crystal temperature has settled. Keep both error relative to nominal and change relative to the sample's room-temperature baseline. The first goes into the board budget, and the second helps identify the temperature contribution. Use a buffered output or an approved low-loading method because a probe on the crystal can change its frequency. Keep the lot number, test firmware and board temperature beside the readings.

Use a hypothetical chamber record to practice the distinction. A sample measures 48,000,960 Hz at room temperature and 48,003,840 Hz at an approved hot point. The final frequency is 80 ppm above nominal, while the change from baseline is approximately 60 ppm. If the other conditions are equivalent and a repeat confirms the change, the sample may meet the DS drift limit while exceeding the ES limit. Even if the board remains within its overall frequency budget, investigate the suffix, measurement uncertainty or part conformance. Save both ratios separately instead of recording only the board verdict.

An assembly change can obscure the difference. If a board was reworked for a poor bypass-capacitor joint, first check the actual load capacitors, ground pads and rework history before comparing the two crystals. A single chamber reading taken while temperature is still rising may call for a repeat with better soak conditions. The aim is a repeatable decision at the same limits, with evidence tied to the tested pieces.

Even if the system ambient rating is below the crystal’s upper limit, check local temperature at the installed location. A regulator or processor can heat the crystal in an enclosure. Conversely, if a build is certain to use a narrower range, ask engineering to use guarantees applicable to that range. The wide-range drift limit does not generally scale in proportion to a narrower temperature interval.

Put the controlling fields on the order

Under the example budget, ES remains a candidate pending validation. DS needs a new worst-case analysis and board data before approval. The order should include the 48 MHz passive crystal designation, 10 pF load, maximum ESR, ±30 ppm initial tolerance, approved temperature stability and complete part number. If the stability letter on incoming stock differs, treat it as a proposed substitute even if the temperature range is identical. Have the assembler scan the complete part number and link first-article chamber data to the production lot so the decision can be reconstructed later.