150 MHz LVDS: how to verify the ECX-L37BN-150.000 temperature range and frequency error together

The same control board has to run inside a hot enclosure in summer and power up after a cold soak in winter. The request says “150 MHz differential,” and the quote comes back with “±25 ppm.” Ask what temperature range that number covers, then check supply voltage and output format. ECS lists 150 MHz LVDS oscillators in the same 7.00 × 5.00 mm package whose temperature range and frequency limit change with two letters in the part number.

Read the frequency limit and temperature range from one row

ECX-L37BN-150.000 is a surface-mount crystal oscillator. ECS uses ECX-L for LVDS, 3 for a 3.3 V supply and 7 for the 7.00 × 5.00 mm package. The B gives the ±50 ppm stability grade, N gives −40 to +85 °C, and the final number is the nominal frequency in megahertz. ECS lists all three 150 MHz configurations below. ECS ECX-L ordering list · ECS ECX-L datasheet and numbering guide

ECS part numberNominal supplyFrequency stability and operating range
ECX-L37BN-150.0003.3 V±50 ppm, −40 to +85 °C
ECX-L37CM-150.0003.3 V±25 ppm, −20 to +70 °C
ECX-L27BN-150.0002.5 V±50 ppm, −40 to +85 °C

All three have the same frequency, package size and output format, and ECS lists enable/disable for each. If your project requires ±25 ppm from −40 to +85 °C, the first row gives a looser frequency limit and the second gives a narrower temperature range. Ask for one complete part number with manufacturer documentation supporting both requirements. The numbering guide decodes the fields. Verify the actual combination in the ordering list or with ECS. ECS listed configurations

Use the temperatures the oscillator will experience across the seasons

Suppose a technician measures −28 °C near the oscillator before a winter cold start. In summer, with the enclosure closed and nearby circuits loaded, the same point reaches +76 °C. This puts both observations outside the CM grade, by 8 °C at the cold end and 6 °C at the hot end. The BN range covers those observations. If the product is specified to operate from −40 to +85 °C, plan the evaluation against both specified endpoints, using the required supply, load and startup conditions.

Write down where temperature is measured. Outdoor air, enclosure air and the oscillator’s local environment can give different readings at the same time. For the cold test, let the board settle at the test temperature and then cycle power. For the hot test, run the equipment under its specified load and wait for temperatures to settle. Intermediate steps or a sweep can reveal a frequency excursion between the endpoints. Record the temperature near the oscillator along with the readings.

Translate ppm into what the counter should read

Divide the nominal 150,000,000 Hz by one million to get 150 Hz per ppm. The ±50 ppm band is ±7,500 Hz, or 149.992500 to 150.007500 MHz. The ±25 ppm band is ±3,750 Hz, or 149.996250 to 150.003750 MHz. Suppose a reading taken under the agreed conditions is 150.004500 MHz. That is +30 ppm, inside the ±50 ppm numerical band and outside the ±25 ppm band. For a formal decision near either edge, account for the counter reference, gate time and measurement uncertainty.

ECS counts the initial tolerance at +25 °C, operating temperature, changes in supply and load, shock and vibration within the ECX-L stability figure. Budget those effects once. The datasheet lists first-year aging separately as ±2 ppm at +25 °C, equivalent to ±300 Hz. For an illustrative first-year budget, adding ±50 ppm and ±2 ppm in the same direction gives ±52 ppm or ±7,800 Hz. A design allocation of ±55 ppm would leave 3 ppm, or 450 Hz, under that assumption. An allocation of ±50 ppm for the entire first year and operating range calls for a tighter part budget or a manufacturer-backed long-term limit. Check what ECS can guarantee for aging over the required temperatures and service life. ECX-L frequency stability footnote and first-year aging test conditions

Check the 3.3 V supply and the LVDS input separately

ECS specifies 3.135 to 3.465 V for the 3.3 V option. A 3.3 V rail with ±3% static tolerance would have a lower limit of 3.201 V. If a 90 mV dip occurs at that lower limit, the oscillator could see 3.111 V, below the specified minimum. Check the supply at the oscillator VDD pin during power-up and under load. For a board with only a 2.5 V rail, the complete 2.5 V part number can go on the candidate list for pin and receiver checks. ECX-L supply options

An LVDS receiver reads the voltage difference between the lines and also has an input common-mode range. LVDS, LVPECL and HCSL have different swing, bias and termination requirements. ECS specifies a 100 Ω load across the ECX-L outputs. If the receiver already has an enabled 100 Ω internal termination, adding 100 Ω at the same node produces a 50 Ω load. Review the receiver’s input mode, termination settings, swing and common-mode limits, and AC or DC coupling before measuring. Include the load introduced by the probe or test fixture. ECS output load · TI guidance on LVDS termination

Also check pin 1 during reset. The datasheet describes an internal pull-up that enables output when the pin is left open. If the clock must stay off until reset releases, verify how the board drives that pin during reset. ECS lists output-enable time and power-up startup time separately, and its startup entry specifies a +25 °C condition. For a −40 °C startup test, time from the defined power or enable event until the receiver sees a usable clock, then record frequency and voltage levels.

Put the conditions you will accept on the quote request

A request might read, “Please quote ECS ECX-L37BN-150.000, 150 MHz, 3.3 V, LVDS, 7.00 × 5.00 mm, ±50 ppm over −40 to +85 °C. Provide the full part number, applicable datasheet revision and packing. State available quantity, quote validity and lead time separately.” If ±25 ppm is a firm requirement across that temperature range, put both limits in the request and ask for a part number and manufacturer documentation supporting the combination.

On the sample report, record the part number, lot, board revision, local temperature, VDD, termination and enable state alongside the readings. A screenshot showing 150 MHz then has a traceable set of test conditions you can use again for future lots. Use the ECS ordering entry to check technical suitability and the supplier’s reply to confirm the terms for the order.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.