An EFR32MG24 wireless board uses a 39 MHz passive crystal. Engineering plans to use HFCLKOUT as a reference for another circuit. The measured reference shifts slightly after that output is enabled, and purchasing wonders whether the crystal lot is out of specification. Check the test state first. Silicon Labs specifies a frequency-shift term for enabling HFCLKOUT under an assumed crystal pullability. The incoming crystal tolerance, installed load error, and output state can be measured separately and used for different decisions.
Record the output state and oscillator conditions
The EFR32MG24 HFXO data sheet lists 39 MHz test conditions with crystal series resistance, load capacitance, and startup information. HFCLKOUT is an output to external circuitry and has its own load, amplitude, and oscillator frequency-shift entries. Two boards using the same 39 MHz crystal can be in different states if one powers an external clock receiver and the other disables the output. If a supplier or technician reports a single frequency-error value, establish whether it was measured on an incoming crystal, an assembled wireless board, or a system driving an external clock load.
Trace the actual network and connected load. Some product options leave the receiving part unpopulated, and even adding a probe changes the load. Record the parts installed, the external module’s power state, and the observation method. Probing the crystal pins can disturb the oscillator. Where a characterized observation point is available, use the same instrument and path for both measurements. A difference between readings from two different physical nodes cannot simply be assigned to the crystal.
Convert the 4.5 ppm scale to hertz
The data sheet lists a frequency-shift range of −1.5 to +4.5 ppm with HFCLKOUT active, under an assumed pullability of 13 ppm/pF. At 39 MHz, one ppm corresponds to 39 Hz. The illustrative conversions are −58.5 Hz and +175.5 Hz. Check the sensitivity and operating conditions of the actual crystal if the part changes. This range is not a prediction for every finished board and does not replace the incoming part specification.
For a system budget example, suppose the reference allocation is 40 ppm and other same-direction terms consume 36 ppm. The remaining allocation is 4 ppm. If the effect of enabling HFCLKOUT were +4.5 ppm under those conditions, the sum would be 40.5 ppm, so the example would require evidence or a revised budget. The actual budget should use the range and conditions applicable to the chosen protocol, source, and operating modes. Avoid assuming that typical values measured at a single temperature bound the system.
Use three measurements to isolate the state change
Start with a known assembly at a stable supply and temperature. Measure with HFCLKOUT off, enable it with a permitted load, and measure the steady result. Then turn it off and repeat the first measurement. If the two off readings return to nearly the same value, the difference tracks the state. If the frequency keeps drifting after each transition, inspect supply, local temperature, and any other features that firmware enables at that time. Repeat with the candidate 39 MHz crystal under the same measurement conditions. Keep acquisition time, uncertainty, load, and firmware revision in the report.
Keep absolute error and the change between states separate. If one sample reads +5 ppm with the output off and +8 ppm with it on, the change is +3 ppm. The +8 ppm figure already includes that change. Adding another 3 ppm to the measured total would double-count it. Record both observations, the change, and the applicable limit as separate values.
At 39 MHz, the 3 ppm change in the example is about 117 Hz. Verify the instrument and test path can resolve that scale repeatedly. If disabling HFCLKOUT removes the waveform from that pin, use an observation path that remains valid in both states. Absence of a pin signal is not a zero-frequency oscillator reading. Use the same settling interval after each transition. If both states cannot be observed at a comparable point, develop the measurement method with the reference board before approving a substitution.
Ask which specification applies to the actual ordering decision
For the 39 MHz crystal, record the complete order code, load capacitance, ESR, operating range, and frequency specification. Request pullability information when the system needs it. If a 40 MHz crystal with the same package is proposed, check the protocol-specific crystal-frequency notes and software physical-layer configuration. The HFXO electrical range does not establish compatibility with every wireless setup. For an active oscillator proposal, confirm the available input route and its electrical limits. Finally, record whether HFCLKOUT is always off, always on, or changes with the product mode, so engineering and purchasing can reproduce the relevant measurement.