The ENC28J60 board uses a 25 MHz crystal, but the counter reads 6.25 MHz on CLKOUT. Keep the reading. CLKOUT has a programmable divider, and the datasheet gives a divide-by-four power-on default. After confirming silicon revision and startup conditions, 6.25 MHz can support a conclusion that the 25 MHz reference is running normally. A “25M” mark beside the test point is not enough to reject the incoming crystal because the board divides the signal there.
Why using the reset button can produce a different result
Compare a complete cold power-on with hardware RESET or a software reset. The ENC28J60 datasheet states that those two resets retain the ECOCON clock-output configuration. If the driver previously selected divide by two, the point may still read 12.5 MHz after reset. Calling both a power cycle and a reset command “restarts” can lead two inspectors to apply the same limits to different expected frequencies.
Record the pin probed, reset method, silicon revision and ECOCON COCON field. The table gives 100 for divide by four, 010 for divide by two and 000 for an output that is disabled and driven low. Record the order of register reads and frequency measurements. If the startup driver changes these bits, measure after configuration or capture the startup waveform so the report does not use a default that no longer applies.
If this clock feeds another device, check when that receiver is released from reset once the reading is correct. The datasheet says CLKOUT stays low during the power-on startup timer interval. Check the relevant silicon errata too. Specify measurement at the receiver in a defined startup phase with a defined divider so the check remains useful if software reset handling changes.Microchip ENC28J60 datasheet, clock output section · Errata by silicon revision