Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

25 MHz 3225 crystals: reading 90NNYYB80RG5 on an FA-238 quote

You need a fresh batch of 25 MHz crystals for an existing board. One quote says “Epson FA-238, 25 MHz, 3225.” A second adds 90NNYYB80RG5. The parts might fit the same board, but there are three questions the quote still has to answer. How much will the clock frequency shift with the existing capacitors? Will it start on time after a cold soak? Can the assembly line load the tape as delivered? Epson uses this exact string to illustrate its configuration system. Each field gives you something concrete to ask about.

Read the suffix in seven pieces

The FA-238 is a fundamental-mode surface-mount quartz crystal. Epson gives the family dimensions as 3.2 × 2.5 × 0.7 mm and the frequency range as 16 to 50 MHz. The “3225” shorthand gives the length and width. The crystal relies on an oscillator circuit on the board, so check the pad layout, terminal connections and electrical specification for the exact part. Epson FA-238 family page

FieldMeaning in this example
909 pF rated load capacitance (CL)
NN±20 ppm initial frequency tolerance
YY±30 ppm frequency change over temperature
B−20 to +70 °C temperature range
80R80 Ω equivalent series resistance (ESR). The R gives the unit.
G200 µW drive-level option
53,000 pieces per reel in this configuration example

The guide prints the entry as FA-238 25.00M – 90NNYYB80RG5. Position matters. A G in the drive-level field means something different from a G in the temperature field. Epson also notes that the available combinations depend on the model. If the quote uses the configuration string, ask the supplier to confirm the corresponding Epson Product Number and datasheet for the parts offered. Epson Product Configuration Guide, FA-238 example · Epson instructions for ordering by Product Number

What happens when the BOM says 12 pF and the quote says 9 pF?

For a crystal rated for 9 pF, the nominal frequency is specified at that effective load. In a common oscillator circuit, one capacitor connects each crystal terminal to ground. The crystal sees approximately the series combination of those capacitors plus stray capacitance. With the external capacitors represented by Cg and Cd, and board and IC stray capacitance combined into Cs, the estimate is CL ≈ Cg × Cd / (Cg + Cd) + Cs. Epson explanation of oscillator circuits and load capacitance

For an illustration, assume 2 pF of stray capacitance and equal capacitors on both sides. Two 20 pF capacitors give an estimated load of 12 pF. Two 14 pF capacitors give about 9 pF. If the original board uses the first pair, installing a 9 pF crystal puts it under a higher load than its rating. That can shift the clock frequency. Converting the 3 pF difference into hertz requires the pulling characteristics of the proposed crystal. These capacitor values illustrate the calculation. An actual board evaluation needs to account for the IC’s internal capacitance, layout and component tolerances.

For a repeat purchase, put the original 12 pF requirement back on the quote. If engineering wants to evaluate the 9 pF option, record the board revision, any capacitor changes and the frequency and startup tests. A probe connected straight to a crystal pin adds capacitance of its own. A buffered clock output or an appropriate low-capacitance measurement setup can help engineering evaluate frequency without substantially altering the load.

Why a 550 Hz offset can fail the room-temperature check

At 25 MHz, 1 ppm is 25 Hz. Under the specified test conditions at +25 °C, NN allows ±500 Hz from nominal. The YY figure gives ±750 Hz of change over the stated temperature range, referenced to the crystal’s frequency at +25 °C. Think of recording a starting point for each sample and then seeing how far it moves in the temperature chamber. Epson glossary entries on frequency tolerance and temperature characteristics

Suppose a receiving test uses the specified load and temperature and reads 25,000,550 Hz. That is +22 ppm. With an expanded measurement uncertainty of ±20 Hz, the resulting offset interval is +530 to +570 Hz, entirely beyond the +500 Hz tolerance limit. At ±75 Hz of uncertainty, the interval crosses the limit. Follow the agreed decision rule or retest with a more precise setup. Applying the temperature figure of ±750 Hz to this reading would give the wrong acceptance decision.

Use both figures in the finished product’s frequency budget. If the design requires ±40 ppm over temperature, it has ±1,000 Hz to work with. The example’s initial offset and temperature change could reach their limits in the same direction, using up to ±50 ppm or ±1,250 Hz before load error or aging. That calls for tighter limits or a new budget that accounts for what calibration can remove.

Cold startup depends on the temperature range and ESR

If a device needs to power on immediately after a soak at −40 °C, the example’s B range only extends down to −20 °C. Some datasheets list a wider temperature range under absolute maximum ratings. Check the range in the electrical characteristics table when judging operation. For instance, Epson’s Q22FA23801604xx datasheet specifies −20 to +70 °C in that table. It also lists 25 MHz, 9 pF and ±20 ppm initial tolerance, yet its temperature stability is ±20 ppm and its ESR limit is 50 Ω. Those last two fields distinguish it from the configuration guide’s YY and 80R example. Epson Q22FA23801604xx datasheet

Another 25 MHz FA-238, Q22FA23801839xx, covers −40 to +85 °C in its electrical specifications and has a 50 Ω ESR limit. Its 7 pF load rating still calls for an engineering review on the original board. At startup, the IC’s oscillator needs enough margin to overcome the crystal’s losses. If the IC specifies a maximum crystal ESR of 60 Ω under the chosen conditions, an 80 Ω option fails that screening criterion. A part specified at 50 Ω maximum can move to board testing for startup time and drive power at the required temperature, low supply voltage and power-up conditions. The G in Epson’s example specifies the 200 µW drive-level option. Compare measured drive with the exact ordered part’s datasheet. Epson Q22FA23801839xx datasheet · Epson guidance on startup margin and crystal drive

Ordering 500 pieces means agreeing on how they arrive

A photo of the original crystal helps you compare visible markings. To identify the full part number, match it to the original reel label, BOM or purchase records and pull the corresponding datasheet. A top marking alone leaves load capacitance, temperature range and packing unresolved. The final 5 comes from the configuration guide. The xx in the two Epson datasheets comes from their packing tables. For Q22FA23801604xx, 00 specifies 3,000 pieces per reel and 13 specifies 500 per reel. A distributor offering to supply 500 pieces on cut tape should state that packing explicitly on the quote. Epson datasheet section 5, packing suffixes

Say you are building 500 boards with one crystal per board. If the assembly line expects to use 15 parts for setup and you want five more for repeat inspection, ask for 520 pieces. Have the assembly house check feed direction, leader and trailer tape, and the shortest strip its feeder can handle. For cut tape or a re-reeled shipment, ask for the original reel label and confirm that its lot or date code can be traced to the tape you receive. If the supplier proposes multiple lots, ask for a quantity for each.

A quote request can start here. “Please quote Epson FA-238, 25 MHz, against the load capacitance, both ppm limits, operating range and maximum ESR in the attached BOM. Include the complete Epson Product Number, matching datasheet, actual packing and lot information for 520 pieces, available quantity and lead time.” If your old BOM only lists the family and frequency, consult the reel label or purchase history, or have engineering fill in the electrical requirements. Once both quotes show the same fields, you can tell whether they cover the same component or whether one needs a qualification run.