A reel of Epson FA-238A quartz crystals feeds correctly while the operator indexes it manually. After several automatic steps, the nozzle starts landing toward the edge of the pocket. Receiving measures a few individual intervals. They are all close to four millimeters, so the reel looks ready to release. The part-specific data sheet for this 20 MHz passive crystal gives both an individual pitch and a cumulative dimension. Checking only one interval or adding individual allowances can miss a displacement that matters during consecutive picks. Purchasing needs to identify which packing drawing applies to the delivered lot in addition to confirming its electrical configuration.
Establish the references for the component and the tape
Epson identifies this configuration as X1E0003410061xx, with the last two digits defined by the packing section. It is a 20.000000 MHz fundamental crystal with a 10 pF load, ±30 ppm tolerance at room temperature and 60 Ω maximum motional resistance. Those are electrical order fields. For tape, use the TE0804L drawing in section 5. It identifies carrier width, pitch and unreeling direction. If the material was cut or re-reeled, establish the original carrier and lot. Check whether a splice or cut changed the feature the assembly line uses for positioning. An ordered suffix establishes the agreed packing format. The actual sample still needs to match the applicable drawing.
The pocket center establishes where the feeder should pick the device. The feed mechanism advances the tape using the holes near the edge. Establish which centers the drawing uses and the direction of advance. Measuring from one hole's left edge to another pocket's right edge adds features unrelated to the required span. Keep the start and end points, direction and magnification. Apply the same method when comparing two shipments.
Individual intervals and the cumulative dimension can disagree
The drawing lists both pocket and sprocket pitch as 4.0 ±0.1 mm. Its cumulative specification of 40 ±0.1 mm applies across ten sprocket-hole pitches, using the row of holes advanced by the feeder. Suppose ten consecutive intervals between those hole centers measure 4.04 mm each. Each is between 3.9 and 4.1 mm, but the total is 40.40 mm. It exceeds 40.10 mm by 0.30 mm. Adding the individual limits to obtain ±1.0 mm would describe a hypothetical case with only an individual-pitch requirement. Use the additional cumulative limit given on the actual drawing. Count ten intervals from the starting center. The end point is the eleventh center. Measuring ten centers instead spans only nine intervals and makes a good tape appear about four millimeters short.
Use a checked optical instrument on a flat sample without stretching it. Record zones well away from any splice as well as an area near the problem. Suppose the measured span is 40.09 mm with an illustrative uncertainty of ±0.04 mm. The true value could cross the limit. Apply the agreed decision rule or repeat with a more suitable fixture. Ask the supplier and the receiving lab to measure the same strip with the same datum before deciding which setup requires correction. Preserve the free-state measurement if the tape passes only when pulled taut.
Link the measurement to the pick position
Number successive pockets on a traceable strip of 20 MHz crystals. Retain the measurement images and pickup records. Run a known-good tape in the same feeder, then reproduce the problem with the candidate reel. A problem concentrated around a splice calls for a check of alignment, hole spacing and cover tape. A steadily increasing offset at different positions calls for checking the cumulative pitch, sprocket pressure, feeder calibration and software indexing. Compare a single bad pocket with the part orientation and packing photographs. Incoming defects, equipment and inspection can produce similar pickup errors. Recorded positions help locate the cause.
Keep the dimensional check and feeder run together in the lot record. The first needs a consistent longitudinal datum. The second needs the recipe, feeder ID and initial pickup offset. A correct longitudinal span does not establish lateral alignment between a pocket and its corresponding sprocket hole. If ten-pitch spans pass but all picks are shifted to one side, check the drawing's edge-to-hole and hole-to-pocket transverse dimensions. Record any temporary pickup offset separately so the next conforming reel can run with the approved settings.
Repeat the test from different start points. Load known-good and candidate tape from early and later positions and run the same number of steps at the same speed. An offset that begins at the same machine step suggests a motion or software check. One that follows a marked physical segment suggests a tape investigation. That distinction informs whether to hold a reel, switch feeders or correct the placement program.
For this 20 MHz passive crystal, put the complete Epson number, packing suffix, drawing and agreed measurement procedure in the order attachment. If the tape meets the cumulative dimension but still feeds poorly, retain it for a production-line check and resolve equipment conditions. A repeatable out-of-limit span warrants holding the associated packing lot and sharing the original measurement points. After a replacement arrives, use the same inspection and feeder setup to confirm it.