An old purchase order calls for an Epson FC-12M at 32.768 kHz and 8 pF. The family brief lists common loads of 7, 9 and 12.5 pF. A supplier may offer 9 pF on the strength of that list and the matching outline. Before changing the order, look up X1A0000610030xx. Epson published a detailed 8 pF specification for this 32.768 kHz passive crystal. Review the family options, exact electrical fields and last two packing digits separately.
Put the 8 pF specification and packing together on the order
The first page of X1A0000610030xx states the frequency, 8 pF load and ±20 ppm room-temperature tolerance. Section 5 defines the final two digits. Code 00 represents 3,000 per reel, 18 represents 5,000, 12 represents 250, and 01 denotes cut tape in a bag. Codes 00 and 18 use the same detailed electrical specification with different deliveries. Have the supplier confirm the full part number and state whether the delivery is a whole reel, cut tape or another packing arrangement. The table alone does not establish that a packing option is immediately available.
The family brief directs customers to Epson for other load values. If an online quote form lacks 8 pF, attach the detailed number and target packing code for written confirmation. Dropping to a nearby capacitance to get past a form creates an engineering change. If the old file only has a plain-language description, retain it for searches and add the exact manufacturer specification to the material record. Without the packing suffix, two electrically equivalent orders can reach the wrong feeder or create confusing returns.
Estimate a one-picofarad change before setting up a test
Take the same 8 pF crystal and increase its actual load from 8 to 9 pF. With the detailed sheet's typical 6.4 fF motional capacitance and 1.3 pF shunt capacitance, a first-order estimate gives about −33.4 ppm, or 1.09 Hz slower. If sustained for a day, that represents about 2.89 seconds lost. Convert 6.4 fF to 0.0064 pF. Multiply half that value by the change in the reciprocal of load plus shunt capacitance. This estimates the direction and scale on the same crystal, using typical parameters. It does not predict how far a different crystal factory-calibrated for 9 pF will be from nominal.
Effective board load also includes the IC and routing. Two 12 pF external capacitors give 6 pF in series, and an assumed 2 pF of stray contribution brings the total near 8 pF. An enabled internal capacitor setting can raise it. Record that setting, the fitted capacitors and the board revision. Read a buffered or divided clock where the design provides one. A probe on an oscillator node adds load to one side, so investigate the changed setup before attributing a slower result to the crystal.
If the old board was calibrated in production, retain an uncorrected frequency reading as well. The firmware might cancel part of the offset and still display normal time after the crystal is replaced. Record the correction register and load settings. Compare both the raw clock and corrected timekeeping, then repeat the low-supply and cold-start tests without a fixture delay that hides a start-up difference. A sample tested on an existing 9 pF board may help identify a part, provided the report names that load revision and stays out of the 8 pF qualification record.
Use the detailed load and drive conditions at receiving
The detailed sheet specifies initial tolerance at 25°C and 0.1 µW drive, with a 0.5 µW maximum drive. Motional resistance is 65 kΩ typical and 90 kΩ maximum. A fixture configured for 12.5 pF would combine loading error with part error. Set it to 8 pF and verify with a traceable reference sample before measuring labeled units from the incoming lot. At 32.768 kHz, ±20 ppm equals ±0.65536 Hz. Record environment, settling and reference settings so a boundary reading can be repeated.
Changing from 18 to 00 can affect the purchase quantity. For 6,000 units and full reels, two 3,000-piece reels meet the request exactly. Two 5,000-piece reels deliver 10,000. Choose according to the actual feeder and build needs and confirm the full packing code. Keep the electrical fixture settings attached to the common detailed specification. Record quantities and reel IDs against each physical delivery. Recover original label evidence when lot information is missing.
Release the 32.768 kHz passive crystal as 8 pF when the exact specification, supplier confirmation and approved sample agree. If only 9 pF is quoted, create an alternate request with the proposed board revision and any capacitor changes, then validate start-up, time error and low-voltage operation. Keep the two loads identifiable at receiving until approval connects the candidate to a specific assembly.