The reference clock only jitters when the buzzer sounds: which sample should you send before changing the Epson crystal?

A small board with a buzzer works normally while silent, but its reference clock shifts briefly when the buzzer sounds. If purchasing sends only a few original and replacement crystals, the supplier's lab may never observe the behavior seen in the assembled unit. Epson notes that periodic mechanical sources such as buzzers and speakers can change a crystal device's output frequency or amplitude. Securing the board in its enclosure can also change how vibration travels. Identify which assembly conditions accompany the fault before selecting another crystal.

Keep the enclosure, mounting points, and sound program on the sample

Record observations with the board bare, mounted in the enclosure with no sound, and mounted while sounding. Mark the buzzer and crystal positions, screw condition, and tone. Use the same supply and measurement point. Preserve the buzzer control timing so changes in the clock can be aligned with its start and stop. If sending a unit to the supplier, include instructions for repeating the tone in test mode and a short waveform that shows the anomaly. If sending only the removed crystal, state that the test is limited to the component off the board.

Document mechanical coupling and supply disturbance separately

Buzzer operation changes current draw, so monitor the supply voltage at the same time. Where practical, change how the sounder is mechanically coupled to the board while keeping electrical connections unchanged, and compare the clock response. Alternatively, investigate power disturbance with the assembly unchanged. Record exactly what changes in each trial and retain an unmodified sample for comparison. When testing mechanical coupling, do not press on the crystal case in place of the specified mounting. Hand pressure can itself change the result.

If changing the distance, damping, or board structure solves the problem, document the effective change in the assembly requirements. If the crystal must change, retest the candidate with the same sound program and complete enclosure before approving substitution. Purchasing can then specify exactly which assembled condition the next batch must reproduce. Epson precautions for use, Section 7