A control board beside a power module needs a 50 MHz crystal oscillator. Its prototype uses Epson's SG2520CAA and passes a room-temperature frequency check. As production approaches, the thermal model shows that the environment near the oscillator may reach 115°C. Purchasing asks whether it can keep the original frequency tolerance and simply order the next temperature grade. Read the manufacturer's ordering table one combination at a time. The letter J appears in two different positions. In one place it codes frequency tolerance and in the other it codes operating temperature. A quotation should identify both positions and the applicable combination.
Put both fields in the request for quotation
The full data sheet places frequency tolerance and operating temperature after the supply field. Epson lists two combinations. JH is ±50 ppm over −40°C to +105°C. LJ is ±100 ppm over −40°C to +125°C. J in the first combination refers to tolerance. J in the second refers to temperature. An internal parts description that says only “grade J” is ambiguous. The full data sheet also lists 50 MHz as a standard frequency. That establishes that the frequency appears in the family table. The order still needs a complete Epson number corresponding to frequency, supply grade, operating temperature and tolerance. The published combinations are JH and LJ. If a project requires both ±50 ppm and operation to +125°C, request a separate confirmation and wait for an applicable written specification.
The data sheet uses a 25 MHz example to demonstrate the positions in its standard product name. For a 50 MHz order, the request can specify SG2520CAA, 50.000000 MHz nominal, CMOS output, the board's supply and the proposed tolerance and temperature combination. Ask the supplier to respond with the complete Epson number and the corresponding specification. If the quotation says LJ and its only attachment is the family cover page or a JH example, ask the supplier to connect both documents to the same specific configuration. Store the two numeric specifications alongside the code so receiving can check the meaning and the markings.
Evaluate tolerance at the temperature the board actually encounters
At 50 MHz, 1 ppm is 50 Hz. The ±50 ppm JH band is ±2,500 Hz, or 49,997,500 to 50,002,500 Hz in its specified range. The ±100 ppm LJ band is ±5,000 Hz, or 49,995,000 to 50,005,000 Hz. Suppose a system permits an error of ±3,000 Hz when the environment at the oscillator reaches 115°C. JH does not cover that temperature. LJ covers the temperature, but its error limit exceeds the system window by 2,000 Hz on either side. Neither published combination establishes compliance with those conditions. If moving the heat source keeps the oscillator environment at or below 105°C, reopen the JH budget. Subtracting 2,500 from 3,000 leaves 500 Hz before aging, measurement and any other system allocations.
A room-temperature sample can also mislead. Suppose an LJ sample is 700 Hz off nominal, or 14 ppm. The reading falls within the narrower band in that test. The unit's measured frequency and its order grade are separate evidence. The footnote in Epson's data sheet includes initial offset, temperature, supply and specified load effects in frequency tolerance. First-year aging at +25°C is listed separately at ±3 ppm maximum. Where the project conservatively adds that item in an applicable budget, 3 ppm at 50 MHz is 150 Hz. Adding it to the 2,500 Hz JH figure gives 2,650 Hz. Check any remaining lifetime, cycling and measurement requirements. Avoid counting supply effects twice or turning the room-temperature first-year rating into a lifetime commitment at 115°C.
Receiving verifies the grade and engineering verifies the temperature
Use chamber points that answer defined questions. Room temperature supports comparison with existing boards and the measurement reference. The limits of the applicable temperature range help verify the ordered configuration. The equipment's worst hot state tests system margin. Record temperature near the device, pin supply, frequency, stabilization time and counter reference. Chamber set point and local operating temperature can differ. Switching the power device changes the board's heat distribution. Apply the same record across lots, including representative low and high supply conditions.
The full data sheet includes temperature characteristic plots for both combinations. Each uses 50 units at 25 MHz. The plots can help illustrate within-sample variation and the measurement setup. For a 50 MHz lot, ask for data tied to the actual manufacturer number and lot, with the load and measurement reference identified. Give particular attention to the limits of the specified range and the application’s worst temperatures. Include a hot restart when the system requires it. Record starting and continuous operation as separate observations on the same board.
Review the voltage field independently. Epson puts T before the tolerance and temperature fields in its name example and also shows a different typical supply range for K. When low- and high-voltage boards share a material entry, use the voltage range confirmed for the exact part and test both applications. This prevents a change from JH to LJ from inadvertently changing the approved supply selection.
Incoming inspection should match the label and complete manufacturer number to the ordered combination before sampling. If the 50 MHz crystal oscillator must be rated to +125°C, the purchasing document also needs the frequency limit for the LJ configuration. For a system that still needs ±3,000 Hz at 115°C, resolve the gap through thermal design, the system tolerance or an applicable written specification. Use samples for temperature testing in the meantime and keep production approval pending until the documentation and board margin both support it.