Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

Specifying Epson SG-8200CJ 50 MHz oscillator tolerance for the first year

A purchasing drawing calls for a 50 MHz oscillator within ±50 ppm across temperature. The system clock spreadsheet adds a separate allowance for first-year aging, and incoming inspection assumes initial room-temperature error has an allowance of its own. By the time engineering estimates a serial clock or timebase error over the three-year warranty, the records contain three different limits. Epson publishes a specification for a particular 50 MHz SG-8200CJ configuration. It gives the team a way to agree on the first-year contributions, the conditions for receiving inspection, and the period for which a separate agreement is needed.

Start with the frequency table for the exact part

Epson maps X1G0062110045xx to SG-8200CJ 50.000000 MHz TJJSA. Its last two digits specify package quantity. The exact specification lists 16 as the standard suffix for 3,000 pieces per reel, giving X1G006211004516. The family brief describes a much wider programmable range under a shorter name. Put the full product number on the order and receiving record, along with model, frequency, and configuration for cross-checking against the supplier’s document. If a quote gives only SG-8200CJ or 50 MHz, request the full code and ask which samples correspond to it. Record an approved packaging change against the actual new suffix.

The frequency table on the first page of the exact specification gives ±50 ppm across its operating temperature range. The footnote includes initial tolerance, frequency variation with temperature, voltage and load coefficients, and first-year aging at 25 °C in that allowance. The family brief also names reflow drift in its tolerance footnote, while the first page of the exact specification does not list it separately. If post-reflow frequency is to determine supplier acceptance, ask which document and conditions apply to the product number, reflow profile, and measurement state in the purchase agreement. Keep the revision and the written response with the order. A family footnote alone provides insufficient evidence of a separate reflow guarantee for a shipment.

Read a sample that is 1,800 Hz high

At 50 MHz, 50 ppm is 2,500 Hz. The nominal band runs from 49.997500 to 50.002500 MHz. Suppose a 50 MHz oscillator measures 50.001800 MHz at 25 °C, 3.3 V, and a recorded output load. This measurement is 1,800 Hz or 36 ppm high, 700 Hz below the upper limit. The difference describes the distance between the current reading and the limit. It does not predict the individual part’s drift over the next year. Temperature, supply, and load can change both the magnitude and sign of the error.

Engineering may specify a separate room-temperature screen, for example ±20 ppm, to reserve margin for other system error sources. That interval is ±1,000 Hz at 50 MHz, and the example part exceeds its upper edge by 800 Hz. If the purchase agreement already specifies the room-temperature conditions, method, and screen, use that additional requirement. If the screen was introduced after samples arrived, record it as a system selection condition, send dispositions and further testing to engineering, and establish whether screened parts can be supplied on future orders. The inspection record will then show the system constraint and how it relates to the manufacturer’s tolerance.

For a reading close to the boundary, include instrument uncertainty and the decision rule. Suppose the measured error is +2,480 Hz with 50 Hz expanded uncertainty under the stated conditions. The upper end is +2,530 Hz. Under an agreed rule that requires the full interval to lie within limits for direct acceptance, retest with lower uncertainty. Record the counter timebase, calibration status, effective gate time, supply voltage, actual output load, and temperature. A check of a known reference source with that counter before testing the suspect device gives both shifts the context behind a borderline reading. Keep the earlier result and instrument identifier with a retest so the record can distinguish a frequency change from a change in reference conditions.

Put a three-year requirement in the RFQ and test plan

Suppose a system requires this oscillator’s timebase contribution to stay within ±60 ppm or 3,000 Hz over three years. The first-year rating takes 2,500 Hz of that budget. The remaining 500 Hz is 10 ppm available to all uncovered terms together. Epson’s detailed document describes aging estimates based on environmental reliability tests and says they do not guarantee the product lifecycle. Send the supplier the three-year requirement, operating temperatures, post-reflow state, power cycling, and allowable calibration strategy. Ask which period, ordering code, and evidence the supplier can support. If the product can be recalibrated in service, document whether that corrects system error or belongs to the component acceptance criteria.

Keep receiving and design qualification on separate schedules. At receipt, check the reel label and paperwork against X1G006211004516 or the approved actual packaging code. Record readings under the agreed supply, temperature, and load. At design qualification, repeat at the agreed voltage and temperature points on production-representative boards, retaining same-device readings and conditions before and after reflow. Before an aging assessment, specify the initial measurement window, retest schedule, storage or operating conditions, and method for following the same units. Tie any supplier evidence to the same part number. When someone adds another 50 ppm for first-year aging or writes 50 ppm against year three, procurement can identify where the number came from and decide whether to place an order, request samples, or obtain written evidence.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.