Pin 3 on the Epson TG-3541CE 32.768 kHz TCXO is a supply connection in the short data sheet and a TEST terminal in the detailed technical sheet. An old board may tie it to the supply while a new library symbol names it TEST, triggering a review exception. A worse mistake is copying the new names and leaving all six TEST pads floating. Start by attaching the complete part number and both documents to the same review. Engineering should take each required net from the detailed footnotes, then check the physical bottom view against the PCB. The label and a frequency reading from one old board provide too little evidence for that decision.
Six pads with the same name have three connection rules
The TG-3541CE brief identifies groups of supply and ground terminals and says pins 6 and 10 are open. The detailed CE and CEA document labels pins 3, 5, 6, 7, 8, and 10 TEST. Its instructions tie pin 3 to VCC and pins 5, 7, and 8 to ground, and leave 6 and 10 open. Pin 2 is still VCC, pin 9 is ground, pin 4 is output, and pin 1 is the active-high output enable. Comparing pin by pin shows that pin 3 still connects to the supply and that pins 5, 7, and 8 still go to ground. That resolves the document dispute about names. Check the relevant data sheet and approval records before assuming any other manufacturer part uses the same board.
The assembly house needs matching netlist, footprint view, and wiring instructions. For example, the library can retain TEST for pins 6 and 10 and carry explicit open marks in the schematic. The three TEST pads destined for ground must be traceable in the netlist. If the mechanical drawing uses a bottom view but the layout tool shows the component from above, locate pin 1 and work through pad numbers in order. This keeps the supply connection on pad 3 from being mirrored to the other side. Epson also identifies small metal crystal test contacts on the short sides of the ceramic body. Inspect these separately from the ten numbered package terminals. Keep fixture jaws, solder, and conductive debris from bridging a side contact to nearby metal.
The enable thresholds scale with a 3 V supply
A correct netlist is only the first check. The detailed sheet specifies an enable high of at least 80% of the supply and an enable low of no more than 20% of the supply. With 3.0 V at the device, pin 1 requires at least 2.4 V for high and no more than 0.6 V for low. Suppose a processor operates at 1.8 V and its data sheet guarantees at least 1.62 V for an output high. That leaves a 0.78 V deficit against the requirement. A room-temperature sample that happens to oscillate does not close that gap. Determine whether the system needs dynamic clock gating and choose an interface against both sets of limits. For a continuously running clock, verify a fixed high arrangement against the manufacturer wiring as well as the board's shutdown and restart sequence.
To retest the 32.768 kHz active oscillator, connect the pins and supply on a verified board, then measure pins 1 and 4. The external connection example requires at least 0.1 µF of supply bypass capacitance and includes the oscilloscope probe in the CMOS load. Check for a high-impedance output when enable is low and a continuous nominal clock when enable is high. Pullups or leakage on a fixture can leave a high-impedance node at a fixed voltage. Use evidence from the actual load to check that mode. Record the measured supply and enable levels, output load, open-pad checks, and sample lot. A counter displaying 32.768 kHz alone does not show that the wiring was exercised in the correct conditions.
For a first article with no output, inspect at two points. With power off, follow the netlist to see whether pins 3 and 2 share the supply, pins 5, 7, and 8 share the ground of pin 9, and pins 6 and 10 have no external connection. Then power the board and probe the actual supply and enable near the oscillator pads. A sample can fail to produce output on a miswired assembly and work on the supplier's compliant fixture. Keep both connection diagrams and measurements in that case and correct the board first. If a reference runs on a verified fixture and several units from the questioned lot show no output on that same fixture, follow the purchase agreement for expanded inspection or supplier analysis. Keep the specified open pads free from injected control signals.
Identify the ordered device and record the board disposition
Quote the 32.768 kHz TCXO by its full ordering number. Epson lists X1B000351000100 for TG-3541CE XA and X1B000351000200 for XB. The related CEA with an additional letter A must also be distinguished. If only XA is approved, receiving uses the original label, part number, and lot records even if more than one variant passes a spot frequency measurement. For matching incoming material with a disputed signal name, attach the detailed pages and close the library review with pin-by-pin evidence for supply, ground, and open terminals. If the controlled production file really has incorrect nets, hold the work at engineering review or first article. Issue the production instruction after the corrected netlist, device identity, and test status are confirmed. This keeps a board defect from being mistaken for an incoming part-number discrepancy.