A frequency counter still reads 25 MHz after immunity testing, but the product logged a link interruption. The final frequency shows that operation resumed. To locate the earlier event, define system performance and recovery requirements, then use monitoring that retains short disturbances. IEC 61000-4-2 provides a reproducible system-level immunity method. Use the applicable product requirements and approved plan for severity, operating mode, and acceptance.
Retain observations that establish event order
Save clock-valid and source-change status, reset cause, and an independent continuity or heartbeat indication. For data links, collect packet or reconnection timing. Determine which flags reset clears, which need capture before initialization, and which diagnostic logs rely on the suspect clock. If the oscillator stops both the CPU and its timestamp timer, ordinary software logs may stop with it. Use a surviving reference, external monitor, or retained event hardware where appropriate.
As an example, an independent recorder samples every 10 µs. Its first unlock indication is at sample 1000, its first observed reset at 1001, and its first reset release at 1004. The recorded unlock and reset positions are 10 µs apart and the recorded assertion-to-release interval is 30 µs. Actual transitions can fall between samples. Use finer resolution or hardware timestamps where needed. A 10 µs poll cannot establish that interruptions longer than 1 µs always get detected. Verify the required event coverage with a known stimulus before formal testing.
Compare instrumented and formal configurations
Probe cables, extra grounds, and adapters can alter coupling. Use approved minimally intrusive monitoring, such as an existing isolated diagnostic output or internally retained event state, in the formal setup. Document any added probes on diagnostic runs. If a fault disappears after adding a ground, compare against the approved setup rather than assuming product compliance. Check that the external recorder itself does not miss data when disturbed.
An unlocked indication alone can be ambiguous. The oscillator may continue while a power or reset event clears the flag, or the receiver PLL may unlock while the local clock remains continuous. Where the test setup allows, record oscillator output, supply, and reset together. A continuous clock with a local rail drop before reset directs attention to power. Missing edges before any supply or reset change direct attention to the clock and receiver path. Tie each conclusion to the actual measurement plane.
Set functional criteria before testing
Specify allowed interruption, automatic versus manual recovery, and persistent data checks. A system may allow a network reconnect while requiring its sample clock to remain continuous. If the link recovers in 20 ms but independent monitoring confirms a 2 µs clock gap, record both results. Pre/post checks are evidence for pre/post function. Mark any interval not monitored.
Include event timestamps, operating mode, firmware, test configuration, and recorded sequence. Keep runs that did and did not reproduce the fault with coverage information. Reuse the independent monitoring after connector, layout, or reset changes to see where behavior improved. Component handling and packaging susceptibility require separate evidence from a system immunity test.
If the diagnostic bench can replay known faults, run explicit controls: a controller reset with the reference intact, a permitted clock interruption with controller power maintained, and normal operation without an injected event. Check that logging distinguishes resets, clock loss, and missed data. If the same flag drops for both faults, add an independent signal or event numbering. A change in that flag alone supports only the observed state, not a unique cause.
Second-resolution display timestamps usually identify a trial. To compare events a few microseconds apart, document sampling interval, active polarity, and trigger delay, and check the script against a known event order.