Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Passive Crystals and Oscillator Circuits

Why is a series inductor reserved for the ESP32-H2 32 MHz crystal? Is 24 nH the final value?

An ESP32-H2 prototype can start reliably at 32 MHz and still drop packets near the receiver sensitivity limit. If the failures concentrate on particular channels, inspect the series component on XTAL_P. This is the position where Espressif suggests starting with a 24 nH inductor to reduce the RF effects of crystal harmonics. A change earns its place on the production bill of materials when it improves the relevant radio result and preserves startup across the operating limits.

The schematic checklist calls for a 32 MHz main crystal whose accuracy is within ±10 ppm and treats 24 nH as a starting value to adjust after system testing. The optional 32.768 kHz low-power clock is a separate circuit. Identify the series inductor by reference designator and net before rework so an experiment does not inadvertently change the antenna matching network. Espressif schematic checklist, external crystal and frequency adjustment.

What 24 nH means at two different frequencies

From XL = 2πfL, a hypothetical ideal 24 nH inductor has about 4.83 Ω of reactance at 32 MHz and about 362 Ω at 2.400 GHz. The frequency and ideal reactance are both 75 times higher. The 75th harmonic of 32 MHz is at 2.400 GHz and the 76th is at 2.432 GHz. These are places to look for evidence on a spectrum trace. The arithmetic gives neither the strength of the harmonics nor their coupling into the antenna.

Use the vendor's impedance curve or S-parameters for the actual component. Parasitic capacitance and losses change its response with frequency, and an inductor may appear capacitive above self-resonance. Two parts with the same nominal inductance can therefore behave differently at the frequency where the radio is affected. Keep the full inductor order code, case size, tolerance, test frequency, DC resistance and self-resonant frequency with the qualification record. Murata inductor glossary, including DC resistance and self-resonance.

Get a frequency baseline before changing the inductor

The crystal ordering specification supplies CL. Espressif's first estimate is CL ≈ C1 × C4 ÷ (C1 + C4) + Cstray. Suppose the selected crystal is specified at 10 pF and the remaining load is estimated as 2 pF across the two crystal terminals. Two 16 pF external capacitors give 8 pF in series plus 2 pF, or 10 pF. Two 18 pF capacitors give 11 pF under the same assumptions. That difference is a load estimate. The exact frequency shift depends on the crystal and the fitted board. Keep the stray-capacitance definition with the result so the same contribution does not enter the estimate twice.

Espressif describes using the radio's TX tone mode to observe frequency offset. As an illustration, a steady +29.28 kHz at a nominal 2.440 GHz reads +12 ppm. The same relative error corresponds to +384 Hz at 32 MHz. Once the test setup and reference are verified, the direction in the checklist is to increase the external load capacitance for positive offset. Change one step at a time and check the direction on the instrument. An offset that changes markedly with board temperature calls for checking the crystal's frequency-temperature behavior, stabilization time and nearby heat sources before retuning.

Test the radio and startup on the same candidate

Hold the board revision, crystal, load capacitors, firmware, channel and radio power setting fixed while comparing two inductors. When practical, return to the baseline inductor to see whether the result follows the component. Record transmit frequency offset, output power and spurious content at the frequencies of interest. For receive tests, fix the packet format, packet count, signal level and loss of the measurement path. A near-field probe can help locate a coupling path. Use a controlled RF test to decide whether that path affects product performance.

Consider a hypothetical startup requirement of 10 ms from the specified power-on event to a usable clock state. At low temperature and minimum operating voltage, the slowest observed startup is 8.4 ms for candidate A and 12.1 ms for candidate B. Under that particular criterion, A has 1.6 ms to spare and B exceeds the limit by 2.1 ms. A cleaner spectrum for B would still leave a startup failure to resolve. If the measurement endpoint is the first radio packet, record it as system readiness. Firmware startup, RF calibration and protocol delays can all contribute.

Allow the board to discharge before repeated starts. Keep the supply ramp, CHIP_EN sequence and observation window comparable. If a probe is connected directly to a crystal pin, characterize its loading and document the probe and attachment. For differences between PCB revisions, inspect the series part near the chip, the capacitors on the crystal sides, the ground plane and any high-speed routing underneath the oscillator circuit. Espressif specifies no vias in the crystal clock traces. If moving the antenna or silencing a nearby digital signal changes the symptom, investigate the observed path before ordering a new inductor value. Espressif layout guidelines for the crystal circuit.

Document the approved oscillator build with the PCB revision, crystal order code and specified CL, both fitted capacitor values, XTAL_P inductor order code and the tested lot. When a supplier proposes a different 32 MHz crystal or another 24 nH component, compare the exact parts and change one item first. Repeat frequency offset, cold startup and the relevant radio tests. A change that requires new capacitors or both a new crystal and a new inductor should be released as a qualified combination so production can reproduce the tested circuit.