An Eterna wireless node already uses the ECS-200-CDX-0998. A supplier quotes another 20 MHz passive crystal with the same nominal 3.2 × 2.5 mm outline and a stated room-temperature tolerance of 10 ppm. Approval depends on the part used and what is programmed into the board. The Analog Devices Eterna integration guide identifies validated parts and a specific pair that can share a Fuse Table image. Use it to give receiving, assembly, and programming the same approval record and to keep an unverified part in the engineering stage.
Record the full part numbers and the applicable configuration
The guide's 20 MHz crystal table gives the ECS-200-CDX-0998 and Kyocera CX3225SB20000F0FZZC1 the same footnote. They are footprint compatible and can use a single Fuse Table configuration. The same table lists an ECS-200-CDX-0778 in a 2.5 × 2.0 mm package outside that sharing pair. It also lists the larger ECS-200-CDX-0914. If a quote shortens the item to family and frequency, check the full original code before adding it to the current work order. The approved pair can use two purchase identities linked to one controlled configuration. Verify the other listed parts separately against their own crystal and board requirements.
The guide calls for selecting the actual 20 MHz crystal in the Fuse Table board-support parameters and explicitly describes the shared image for the pair. Its design flow also calls for characterizing the assembled 20 MHz reference and entering the resulting load trim in the configuration. A production document can tie together the part number, PCB revision, approved image identifier, and trim evidence. Before switching sources on an existing board with the shared image, verify assembly, actual trim results, and radio function on a first article. When the PCB, nearby copper, or production programming procedure changes, retain a configuration readback so a repair technician can establish what was loaded.
What does a 200 Hz room-temperature limit establish?
The specific ECS drawing gives the ECS-200-CDX-0998 a nominal 20.000000 MHz, ±10 ppm initial tolerance at 25 °C, a 10 pF load, and a maximum equivalent series resistance of 50 Ω. Multiply 20 MHz by 10 and divide by one million to get 200 Hz. Under the drawing conditions, its room-temperature interval is 19,999,800 to 20,000,200 Hz. This is an incoming limit for that individual part. If two samples read 120 Hz high, those readings both fall within this example window. Matching radio and network behavior on one board still depends on the validated part number, actual configuration, and board tests. The guide separately identifies the roughly 32 kHz reference used for precise long-term timing. Record that result separately from the radio reference.
Assembly can introduce a different problem. The guide lists body outlines of 3.2 × 2.5 × 0.8 mm and 3.2 × 2.5 × 0.9 mm for the pair. Even with matching planar dimensions and footprint, check height limits, enclosure clearance, and placement settings. For example, if nominal space from the PCB to the housing is 0.95 mm, a listed 0.9 mm body leaves only 0.05 mm nominal clearance. That merits a mechanical review. Use the actual maximum dimensions on both drawings and allow for tolerance on the surrounding assembly. If the normal fixture measures frequency on a bare board, repeat the appropriate check with the shield or housing fitted so an assembly issue can be distinguished from an incoming frequency problem.
Decide who retains the first-article evidence from programming. Suppose two programming stations process one pilot lot. One uses an old local file and the other uses the approved work-order image. Similar room-temperature frequencies would reveal little about which image was installed. Lock both stations to the approved revision and attach the programming log or a readable version identifier to each sample record. Where production security settings restrict readback, retain a successful programming record under the permitted workflow and have the stations verify the project image checksum. This keeps the supplier frequency report useful for incoming inspection and the calibration evidence traceable to the board.
Preserve the board record when switching to the second source
Receiving can allocate both approved materials under the shared configuration while preserving the original code and lot on each reel. For first article, use the same PCB revision and test a board from each source in parallel. Record the programming identity before and after loading, board trim results, and any project-specified cold-start, network-join, and communication checks. If results disagree, establish whether the mounted part and configuration match before investigating frequency or RF performance. A generic part supplied merely at the same frequency can be handled as an engineering sample while remaining outside the live order. Obtain a traceable mapping for any shortened package label so later reviews identify the specific material revision.
Repair can use a different workflow from production. When a batch requires replacement parts, look up the board's work-order revision and loaded configuration before selecting the image or repeating a calibration check. If another board revision uses a smaller crystal on different pads, select its own drawings and manufacturing instructions even when the same counter displays nominal frequency. Put the two approved 20 MHz passive crystals, the shared image, and their limits in the repair instruction so the technician can go from the mounted part to the applicable process. For a candidate outside that list, start the change record with radio verification and configuration revision and approve substitution after the evidence is available.