A differential oscillator feeds a fanout buffer. Integrated jitter is 80 fs at the input and 100 fs at the output. The buffer's added random timing variation cannot be inferred by directly subtracting RMS values. For independent, uncorrelated terms with the same bandwidth and measurement conventions, estimate the added contribution from their variances.
Identify which quantities can be subtracted
In the ideal example, the additive term is √(100² − 80²), or 60 fs. The 20 fs figure is simply the difference of the RMS readings. First confirm the same integration band, carrier, load, output format, and spur treatment. Even the same source routed through different input interfaces or paths can encounter different residual instrument noise.
When output and input are nearly equal, the squared difference is sensitive to small reading changes. An output reading slightly below the input does not imply negative additive jitter. Clipping the result to zero also does not prove perfect performance. Check whether input jitter dominates, evaluate instrument floor and repeatability, and consider the manufacturer's residual phase-noise method.
Tie acceptance to the system budget. Where total output jitter is the limit, test the final clock directly. To compare buffers, hold input noise and fixture conditions constant. Retain the raw phase-noise curves for input and output to locate the added noise and identify correlated supply-coupled spurs. If output swing or drive can be selected, repeat with the actual order configuration and load. Avoid budgeting with only the best lab setting.TI guidance on measuring additive jitter in fanout buffers