How can one 160 MHz clock edge measure 0.64 ns and 0.84 ns on the same oscilloscope capture? The readings can both be right if they time different parts of the voltage transition. On the Fox FO3SL, 0.7 ns is the maximum rise and fall time for nominal frequencies above 100 MHz through 160 MHz, measured between 20% and 80% of the output swing. A receiving inspection set to 10%–90% counts two additional portions of that edge. Comparing its reading directly with 0.7 ns can send conforming parts back to the supplier. Abracon / Fox FO3SL data sheet, Rev. A, electrical characteristics on page 1
What do 160 MHz, 0.7 ns and 3.3 V tell you?
160 MHz is the rate at which the clock repeats. Its reciprocal is 6.25 ns, the nominal spacing between successive rising edges. With exactly 50% duty cycle, the midpoint of a falling edge follows the midpoint of the rising edge by about 3.125 ns. Rise time describes how long a single transition spends between two designated voltage levels. Two clocks can repeat at the same rate and deliver different edge shapes to a receiver. The data sheet also lists output symmetry of 45%–55%. That measurement uses the 50% crossing of the output swing to locate each edge. The rise and fall measurement uses two crossings on each edge.
The FO3SL, formerly F300SL, is a 3.2 × 2.5 mm oscillator with HCSL differential outputs and a 3.3 V ±5% supply rating. That puts the rated supply range at 3.135 to 3.465 V. The voltage percentages used to time an output edge are referenced to the measured output swing. The same data sheet also uses 20% and 80% of the supply voltage to specify low and high levels at the output enable pin. Label the reference quantity in the inspection program so the two sets of percentages lead to the intended checks.
- 13.500 to 100.000 MHz
- Includes 100.000 MHz. The maximum for each rise and fall time is 1.0 ns.
- Above 100 to 160.000 MHz
- Includes 160.000 MHz. The maximum for each rise and fall time is 0.7 ns.
Choose the row by the nominal frequency of the ordered part. A BOM line at exactly 100.000 MHz uses the 1.0 ns row. For a 160.000 MHz order, carry the 0.7 ns limit and its measurement conditions into the inspection attachment. Abracon / Fox FO3SL frequency bands and transition-time limits
Four crossings explain the two answers
Here is a worked example with invented voltages and times. Imagine observing one output relative to ground. Its low plateau is 0.05 V and its high plateau is 0.75 V, so the swing is 0.70 V. Calculate each threshold by adding the chosen percentage of the swing to the low plateau. That gives 0.19 V and 0.61 V at 20% and 80%, and 0.12 V and 0.68 V at 10% and 90%. On a real capture, match the method used to identify the high and low states. If the software derives them from the extremes of the trace, overshoot and ringing can shift the thresholds it reports.
- 20%–80% rise
- Suppose the voltage crosses 0.19 V at 0.17 ns and 0.61 V at 0.81 ns. Subtracting gives a rise time of 0.64 ns.
- 10%–90% rise
- On that same edge, suppose it crosses 0.12 V at 0.08 ns and 0.68 V at 0.92 ns. Subtracting gives 0.84 ns.
- 80%–20% fall
- On a separate hypothetical falling edge, suppose it crosses 0.61 V at 3.37 ns and 0.19 V at 4.03 ns. The fall time is 0.66 ns.
The wider rise window adds 0.20 ns in this illustration. The bottom portion, from 10% to 20%, adds 0.09 ns. The top portion, from 80% to 90%, adds 0.11 ns. The time spent in each portion depends on the shape of the edge. A fixed conversion factor assumes a specific shape, which may change with termination, probing or ringing. Recalculate from the original samples using the applicable thresholds. When a report supplies only the 10%–90% number, request the capture or a repeat measurement with 20%–80% thresholds and the accompanying setup details.
Where does the 50 Ω load go, and where do you probe?
The FO3SL electrical table lists a 50 Ω output load to ground. For HCSL, draw the ground path for each output when laying out the fixture. A 100 Ω resistor across the two outputs provides a path between the lines. Two 50 Ω resistors to ground also provide a path from each line to ground. Check the fixture, scope input and receiver for built-in terminations before connecting them. If an existing 50 Ω load to ground is paralleled with another 50 Ω path to ground at the same node, the effective load becomes 25 Ω. That can alter the swing and move the voltage crossings. Renesas AN-879, traditional HCSL termination diagrams
A single-ended probe measures one output relative to ground. A differential probe or a scope subtraction measures the instantaneous voltage difference between the outputs. Each waveform has its own high and low plateaus and therefore its own percentage thresholds. The public FO3SL electrical table gives the load and voltage percentages, but its rise and fall row leaves the probe location and fixture details unspecified. Ask the supplier to confirm the manufacturer’s measurement node, the termination circuit and whether the stated reading uses a single-ended or differential waveform before making 0.7 ns a lot-rejection criterion. For a test at the receiving IC, get the applicable HCSL connection, voltage limits and edge definition from the receiver documentation.
For a discrepancy of tens of picoseconds, investigate the measurement chain first. Evaluate the scope, probe, cables and fixture together and compare step response specifications at the same voltage percentages. Verify the chain with a known edge, then check the bandwidth limit, effective sample rate and vertical range. Align the time delays of the two paths if you subtract channels. At 5 GSa/s the sample spacing is 0.20 ns, so a 0.70 ns transition spans about 3.5 sample intervals. At 20 GSa/s it spans 14 intervals. Finer time sampling helps locate crossings, and the result still depends on analog bandwidth, probe loading and repeatability. Tektronix ABCs of Probes, system bandwidth and rise-time measurement
What evidence should accompany the order and the test?
- Purchasing confirms the exact orderable configuration.Ask the supplier to map the full order code to 160.000 MHz, HCSL, 3.3 V, frequency stability, operating temperature range and packing. Request current availability for that combination. The page 1 table lists stability and temperature options whose frequency ranges extend to 160 MHz. Page 3 qualifies combination availability. The lower bound of the warmer operating range is −20 °C in the page 1 table and −10 °C for code E on page 3. If ordering that temperature option, get the rating for the quoted part confirmed in writing. Abracon / Fox FO3SL options and ordering notes
- Incoming quality reproduces the agreed component test.Record the part and lot, actual supply voltage and temperature, load schematic, measurement node, instrument settings, plateau method and both rise and fall results. Save the original samples and the number of cycles evaluated. For a 20%–80% result close to 0.7 ns, apply the agreed repeatability and measurement uncertainty rules. A discrepancy with missing setup information calls for a comparable measurement before a lot decision.
- Engineering checks the clock where the receiver uses it.Check amplitude, common-mode voltage and ringing near the receiver threshold on the finished board. Record the 10%–90% result separately if the receiver requires it. If the oscillator meets its component edge limit in the agreed fixture and the board clock still misbehaves, investigate termination placement, trace reflections, arrival-time skew and receiver configuration. The fixture and receiver captures give the two teams a way to locate where the waveform changes.