Buying a 38.4 MHz active oscillator for FX3. Which phase-noise points should the supplier certify?

A quote for a 38.4 MHz active oscillator on a CYUSB3014 FX3 board often gives the frequency, temperature range and a small RMS jitter number. To decide whether the device fits, ask how that number was obtained. The FX3 data sheet includes phase-noise limits at several offsets from 100 Hz to 1 MHz in its input-clock table and specifies edge and duty-cycle requirements separately. A low-jitter product summary needs supporting measurements or guarantees for the applicable offsets before the buyer can use it for receiver acceptance.

Put the offset points on the RFQ

The manufacturer gives upper limits of −75, −104, −120, −128 and −130 at offsets of 100 Hz, 1 kHz, 10 kHz, 100 kHz and 1 MHz. The table labels them in dB. Oscillator reports commonly express normalized phase noise in dBc/Hz. Attach the manufacturer table and its revision to the inquiry, ask the supplier to state the quantity and reference conditions, and confirm comparability with the receiving-device manufacturer where needed. Require the trace for the quoted frequency, supply, load and ordering suffix. A good plot for another frequency in the same product family can help with screening.

Suppose the two parties agree that the units and methods match. The candidate reads −101 at 1 kHz against a limit of −104. It is 3 dB above the limit, approximately twice the allowed linear noise power spectral density. At 100 kHz it might read −135, which is 7 dB below that offset's limit of −128. The latter result does not change the failed 1 kHz point. If the quote's integrated jitter starts at 12 kHz, it omits the 1 kHz data entirely. Keep the original trace, readings and pass decisions for each offset on the inspection record. Record integrated jitter in a separate field.

Close-in measurements can be difficult. If a report cuts off its lowest offsets, find out whether the analyzer range, fixture noise floor or missing tests for that lot are the cause. Request the setup for the required offsets, a noise floor that can distinguish the limit and a statement of how discrete spurs were handled. Use a repeatability check appropriate to the project. A smooth curve between available offsets does not supply missing measured points. A calibrated counter still helps establish center frequency, independently of any conclusion on close-in phase noise.

Check the stuffing option and the waveform at the receiver

FX3 accepts a 19.2 MHz passive crystal between XTALIN and XTALOUT. The 38.4 MHz frequency belongs to the external-source list. Apply it to CLKIN and set FSLC[2:0] to 110. On the assembly drawing, show the unused crystal network, the installed oscillator and the active strap positions. A same-size 38.4 MHz passive crystal or a same-family 52 MHz active oscillator needs a schematic and strap review. FX3 also supports the latter frequency in another setting. That compatibility does not authorize it for the 38.4 MHz assembly.

Measure the clock at the point specified for receiver acceptance. The input table lists a 30% to 70% duty cycle, rise and fall times of at most 3 ns, and limits for overshoot and undershoot. A 38.4 MHz clock has a nominal period of about 26.04 ns, of which 30% is about 7.81 ns. That calculation helps put the waveform in scale. It is not an extra manufacturer pulse-width specification. Record edge thresholds, probe loading, ground reference and actual levels on a production-representative supply and layout. A source that meets frequency can still produce overshoot at the pin when the route or load changes.

If one source will feed two receivers, confirm whether the design uses independent outputs, a fanout buffer or an approved branch on a single line. Measure noise and edges on the final topology. Have the lab say whether it measured at the oscillator output or after the buffer at the receiving input. Compare under equivalent supply conditions. If close-in noise improves only when another load is disabled, investigate the regulator, grounding and switching load on the actual board. Asking the oscillator vendor for lower noise alone can misattribute noise introduced downstream.

The external input table lists a maximum deviation of 150 ppm, or ±5,760 Hz at 38.4 MHz. Ask which temperature, supply, load and aging terms are covered, then apply the project's actual total budget. Frequency margin cannot offset a phase-noise or edge failure. If the first build was only exercised at a low connection speed, preserve representative high-speed operating conditions for later lots and retest cold start and hot steady state. Tie the test to the clock part, board revision, straps and observed evidence. Keep functional and waveform checks together since the data path has its own timing and configuration requirements.

Decide when to release the part

The sampling report should also address borderline results. Suppose the limit is −128, the reading is −129 and the method uncertainty is ±2 dB. The unfavorable endpoint reaches −127. A project that requires measurement margin should hold the result for retest with better dynamic range or an improved fixture. The trace screenshot alone cannot support that decision. Preserve the tested carrier frequency, calibration record and instrument settings so a later lot discrepancy can be reproduced.

The purchase order should identify the full 38.4 MHz active oscillator number, supply, output, temperature range and mechanical drawing. Reference the approved noise limits at each offset, frequency-deviation definition and test method. If the supplier provides one integrated jitter figure and cannot fill in the required offsets, keep the offer under technical review pending evidence for the exact part. Once the vendor specifies the limits and first articles meet receiver conditions on the actual load, record the test point, fixture and temperature range in the inspection plan. Even if production does not sweep every unit, keep qualification and controlled sampling evidence traceable to the lot, board number and part revision.