A receiver needs to know the RF power available during its active interval. An energy budget may use the average across the whole period. One meter reports −7 dBm while a gated measurement reports +3 dBm. Both can be valid. Identify the window relative to enable and distinguish pulse-top average, peak envelope power, and long-term average.
Ten percent duty cycle reduces average by 10 dB
Suppose a 100 MHz sine burst runs for 100 µs every 1 ms at +3 dBm, or about 1.995 mW, with negligible off power. The full-period average is 0.1995 mW, or −7 dBm. This duty cycle describes the RF envelope. The alternating carrier already contributes to the measured on power. With 200 µs on instead, the mean becomes about 0.399 mW or −4.0 dBm, even though the on power can stay fixed.
Now include −20 dBm, or 0.010 mW, in the off state. At 10% duty, the average becomes 0.1995 + 0.0090 = 0.2085 mW, or about −6.81 dBm. Adding 10 dB to infer on power would give +3.19 dBm because of leakage. Weight linear powers before converting to decibels. Variable on time, amplitude, or leakage can also change results across averaging windows.
Move the gate to test whether the top is flat
Trigger from enable or a frame marker and capture the envelope from before turn-on until after turn-off. View the clock at the load as well. Suppose the first 8 µs is a ramp, the last 4 µs is a tail, and the receiver needs power during 30 to 70 µs after enable. Measure a 40 µs gated average there and retain separate rise, fall, and peak data. Document which event defines time zero. An RF-derived trigger might miss a weak startup, so an external marker can help cover those starts.
Move the gate slightly earlier and later. A stable plateau should yield similar readings. Entering a transition or an off interval can change the mean. With a zero-span analyzer, check that RBW, detector, and video processing preserve the required envelope speed. Narrow filtering can alter short pulses or create tails in the display. Verify response with a known pulse power, width, and modulation. Check noise floor and dynamic range before treating apparent off-state power as device leakage.
Apply each limit to its own quantity
If the example requirement is +2 dBm minimum average from 30 to 70 µs, +3 dBm with adequate measurement margin supports that check. The −7 dBm full-period mean describes average RF output and does not imply insufficient receive power. A +5 dBm maximum envelope peak requires equipment and bandwidth that can capture overshoot. Supply consumption is another measurement at the supply, since RF power is only one part of the energy budget.
Log the trigger edge, gate width, results after moving the gate, full-period observation time, and path corrections. If the disabled clock emits brief leakage pulses, retain their individual times and amplitudes. A stable mean can conceal them. For changing frame lengths, repeat at each cadence with equivalent definitions of pulse-top and full-period power.
If a low-power mode transmits only once in four periods, each burst can still meet its pulse-top limit. For an hourly budget, average across the supercycle rather than concatenating four on windows. Conversely, including bench setup and unrelated idle time can understate normal operation. Define the start, stop, and number of complete frames from the actual timing schedule.
If the report has room for one field, make the parameter name include its interval, such as average power from 30 to 70 µs after enable. Preserve linear power samples and edge timing markers before calculating mean or peak. A changed receiver window can then be evaluated from the record if coverage is adequate, without reconstructing the envelope from one decibel reading.