An FPGA board calls for 24 MHz. The designer divides the internal high-frequency oscillator by two, and purchasing proposes deleting the external source after seeing 24 MHz in the design. Check frequency accuracy, continuity, and the receiving interface. A clock driving a status light has different requirements from one used for protocol timing. If a reference is needed at an ordinary FPGA global clock input, a bare 24 MHz crystal cannot drive that input by itself.
Identify the clock that the design uses
Lattice's iCE40 UltraPlus datasheet describes an internal 48 MHz oscillator with 24, 12, and 6 MHz options. Its oscillator guide discusses calibration for accuracy and shows a reference feeding counting logic. Check whether the relevant RTL uses the internal oscillator or an external reference. Get the pin assignment, clock constraints, and consumer list. If two functions share the clock, identify the tighter requirement.
An external path still requires a suitable circuit. The datasheet describes global inputs and standards for different VCCIO values. Those inputs receive an electrical signal. If the schematic provides only a digital input without a suitable crystal amplifier and feedback path, use an active oscillator, a separate oscillator circuit, or an existing qualified clock. A passive crystal belongs to a design with an applicable oscillator circuit and separate material approval.
Use the divider to check the accuracy assumption
An integer divide-by-two converts 48 MHz to 24 MHz. If the input were 48.48 MHz, the output would be 24.24 MHz. Both have 1% fractional error, or 10,000 ppm. The number illustrates division, not Lattice's device limit. If an interface requires an absolute 24 MHz accuracy of ±50 ppm, the window is ±1,200 Hz. A divider sets nominal frequency. Datasheet evidence and board tests still need to establish the result across operating conditions and life.
A wake timer for an LED may allow a wide range. A shared clock for communications, sampling, or synchronizing another chip has to satisfy that interface's accuracy, period variation, and clock-loss behavior. A calibration design still needs a reference, timing for calibration, and logic. Where no such source is available and engineering cannot establish accuracy, keep the candidate external source in the BOM review.
Check voltage and startup for the external option
Ask for voltage, guaranteed output format, pinout, temperature, and total accuracy. Match the device's output ratings to the selected FPGA I/O bank, especially when 1.8 V and 3.3 V coexist. If the oscillator starts first, check the device specifications for input behavior before the FPGA supply is up. For a controllable oscillator, confirm its default state and whether the clock is available during configuration or wake.
Keep separate trial records for internal and external modes. Check frequency, timing, and the actual operating mode at appropriate points after configuration. With an external oscillator, retain the waveform at its output and the receiving pin. If 48 MHz is still running internally, use the constraints and logic behavior to identify which domain drives the function. Label each capture with the path. Update both logic clock constraints and allowed board populations when changing the source.
For the external option, measure actual startup on the fixture. The new oscillator may be running while the logic waits for another clock. Time power to valid output separately from configuration completion to useful operation, and record any calibration wait.
Check whether another controller needs the reference before the FPGA starts. A host may perform configuration, while a different interface opens only after configuration. These uses impose different clock availability requirements. Verify startup delay, input levels, and any gating. A steady clock measured after configuration does not address the earlier interval. If the design switches clocks, document the transition and which consumers stay in reset. Preserve the first failed edge or error count and record the external clock's role by board revision.
Keep each external supplier's approval tied to its actual option and samples. Factory-programmed options need a confirmed delivered configuration. A report on one oscillator does not qualify another. Preserve identification and representative transitions from clock startup to system operation. If a temporary reference calibrates the internal counter, document when that reference is applied and whether the result survives power loss. Deleting a BOM item can add production steps. Include their time and repeatability in approval.
Document the decision for repeat orders
If the internal clock meets requirements under approved conditions, retain the do-not-populate rule and approval. If external accuracy is required, create a material line for a complete active part number, load and logic requirements, and packaging. Link any passive crystal to its separate oscillator circuit and board version. A future expedited build can use the work order to determine the actual path and verify the device against that path, even when suppliers offer the same nominal frequency.