Two running 10 MHz oscillators give 100 ns output periods in steady operation, but switching introduces an extended low interval. The ICS580-01 timing diagram shows the output continuing for several old-source cycles after selection changes, then holding low for a nominal three new-source cycles before following the new clock. Suppressing narrow pulses permits this longer gap.
Capture INA, INB, SELB and output on a common timebase. Mark the last valid old-source edge and first valid new-source edge. With two 10 MHz clocks, three cycles of the new source are about 300 ns. This helps choose the capture window. The datasheet labels the behavior nominal, so it is not a guaranteed upper limit for total switching time. With different input frequencies, record the direction because the new-source period depends on it.
Test separately with the original source stopped and note whether it stopped high or low. The datasheet shows distinct timing for this case, and the NO_INA indication also depends on the timeout selected by DIV. Check whether the board feeds the indication back to the selection input for automatic switching. An alarm alone does not mean the selection changed. Time detection, selection response and output recovery separately to explain the interruption.
If the customer requires the receiver to stay out of reset, compare against its maximum tolerable edge-free interval and reset policy. Searching only for narrow pulses can miss a long low interval. Retain the minimum and maximum pulse widths around switching and receiver status to assess whether this multiplexer fits the application.Renesas ICS580-01 datasheet, Figures 1 through 3