A dual-channel instrument uses two analog-to-digital converters driven from the same clock source. Connect a common test signal after power-up and both waveforms appear. Restart the instrument and one waveform occasionally shifts by several samples. Before ordering a lower-jitter oscillator, ask whether the shift stays at a fixed number of samples after a given restart or fluctuates randomly from sample to sample. A fixed shift after initialization calls for checking how the converter and digital link establish their common time origin.
Consider a high-speed converter that supports JESD204B Subclass 1. The device clock determines when analog samples are taken. The digitized values then travel through high-speed serial lanes. The receiver aligns lanes, buffers data and releases it at an agreed time. The device clocks may have the same average frequency while their receivers establish frame boundaries on different integer clock cycles. Successful data transfer shows that the link is working. Repeatable end-to-end latency needs a separate test.
Why the interface has a separate SYSREF signal
The device clock supplies a continuous timing grid. SYSREF lets the devices identify a common reference point on an agreed device-clock edge. In JESD204B, the local multiframe clock, or LMFC, defines timing boundaries for the transmitter and receiver. Subclass 1 uses SYSREF to align these references. Some converters also use it to synchronize internal sampling dividers. The AD9208 datasheet describes both functions and the requirements for deterministic latency so you can match them to the logic design.
SYSREF may occur only once or intermittently, but the receiver samples it near a device-clock edge. Trace length, output-to-output delay, driver characteristics and receiver thresholds affect which edge captures it. If SYSREF falls near the edge of its valid window, changes in voltage, temperature or initialization state may move capture by a cycle. Reducing random jitter can improve margin. The layout and relative phase still have to meet the converter's setup and hold requirements.
The receive buffer offers another clue. Data arriving at the receiver may have to wait until the agreed release boundary. If lane arrival is close to that boundary, one initialization can make the release window while another misses it by a whole multiframe interval. A shift near a multiframe period or an integer multiple points toward clock distribution, buffer release or the reset sequence. Review the ADC requirements alongside the particular receiver implementation before reusing buffer settings from somebody else's design.
Separate sampling error from digital release delay
For a hypothetical example, take two device clocks with 1 ns periods and assume direct sampling with no digital decimation. The target is for both outputs to align to the same sample after every restart. Feed the ADCs the same repeatable pulse over matched or calibrated test paths. If nine initializations give zero relative sample offset and the tenth gives sixteen samples, the digital position changed by 16 ns on the tenth attempt. Compare the triggered capture with SYSREF capture and receive-buffer status for that run. To decide whether sixteen samples represent one multiframe, use the actual decimation, samples per frame and multiframe configuration.
For another check, feed the same stable sine wave to both converters. Compare phase and noise over multiple acquisitions. If mean phase after reset is consistent but rapid variation or noise within each capture is significant, examine the analog input, sampling-clock phase noise and measurement bandwidth. If the captured data shifts as a block despite a consistent input-to-sample relationship at the converter, look at receiver alignment and release. Preserve any available SYSREF capture or buffer state with the script and test temperature for later comparisons.
Exercise a full power cycle, a reset of the ADC alone and a reset of the receive logic alone. Software may initialize the devices in different orders for these three operations. When one sequence reproduces the fault, trace clock settling, configuration load, SYSREF generation and link start in time. If testing a change in SYSREF pulse mode or enable order, keep an otherwise identical baseline. It helps distinguish a change in clock behavior from another firmware difference.
If the distribution output mode or termination changes, observe the edges at the receivers again. Equal trace lengths are meaningful when the paths, receiver thresholds and termination conditions are comparable.
Purchasing should provide the actual reference frequency, output interface and number of synchronized outputs. List output delay matching, adjustable step size and required reference-pulse modes for a distribution device. Engineering can then add the converter's setup and hold limits and configuration conditions. Keep two separate acceptance checks: clock quality during continuous operation and repeatable timing boundaries after reset. Attach a waveform and a repeatable sequence to each.