Purchasing is sourcing crystals for a low-power timing board, and a small sample lot measures below 70 kΩ equivalent series resistance. The Jauch JTX210 documentation lists the standard maximum, maxima for particular versions, and low-resistance options separately. The STD and T1 entries, for example, give a standard limit of 90 kΩ and optional limits of 70 kΩ or 80 kΩ. Sample readings within 70 kΩ and ordering the 70 kΩ maximum option on every delivery are distinct forms of evidence.
Set the ESR ceiling from the oscillator circuit
If the host IC uses a weaker oscillator drive in its power-saving mode, establish the worst-case acceptable ESR from the manufacturer's guidance and board-level verification. Record the project's minimum supply voltage, startup time, load capacitance, and power mode together so a change intended to reduce ESR does not inadvertently change the load configuration. If the 90 kΩ standard part provides adequate board-level margin, engineering can approve it on the basis of those results. The distribution in one sample lot need not become a requirement on every order.
Make the quoted limit traceable to the order
Ask the supplier to identify the actual series variant, load, tolerance, maximum ESR, and applicable conditions in writing. If the low-resistance option uses a special drawing rather than a visible suffix, include the drawing number and revision in the order. Save incoming sample measurements as quality records. A sample does not replace a written lot limit, and small samples often contain nothing close to the maximum.
If comparing standard and low-resistance grades, keep separate sample and price records and have engineering evaluate them under the worst actual operating settings. Recheck the maximum ESR if production changes the oscillator drive mode, even if both BOM entries still say 32.768 kHz. Jauch JTX210 standard and low-ESR grades