Do the KDS DSX321G A7T and A7U share the same first-year allowance at 16 MHz?

A board using the KDS DSX321G needs a different purchasing suffix. The supplier sends two sheets that describe a 16 MHz passive crystal, 8 pF load, and 60 Ω. Both top marks show the nominal frequency. If the application is near the previous upper temperature or the frequency budget relies on a smaller annual drift, compare the complete specifications line by line. These parts have the same initial room-temperature limit and differ in operating coverage, first-year aging, and stated qualification evidence. Approval depends on which of those limits the original board uses.

Record the common test conditions and the limits that change

Daishinku lists 7AD01600A7T and 7AD01600A7U as DSX321G, 16.000 MHz, fundamental AT-cut, and 8 pF. Both specify initial ±20 ppm at 25 °C and 60 Ω maximum series resistance. The approval sheet can reuse those common conditions. The bench fixture still needs the correct load and an agreed excitation. The two sheets also list the drive level as 100 µW typical and 200 µW maximum. Confirm conditions for the project. A third DSX321G at the same frequency requires its own exact code and manufacturer specification.

Compare temperature and aging to distinguish the two suffixes. A7T covers −40 to +105 °C, with ±50 ppm over that range. A7U extends to −40 to +125 °C and lists the same ±50 ppm across its own range. First-year aging referenced to +25 °C is ±5 ppm on one and ±3 ppm on the other. The A7U sheet also explicitly states AEC-Q200 compliance. The A7T device summary does not make that statement. If the customer requires qualification evidence, establish which part and lot it applies to and retain it with the order. Evidence for one suffix does not establish omitted conditions for the other.

What does a passing room-temperature sample tell you about the annual budget?

At 16 MHz, one part per million is 16 Hz. The A7T’s 5 ppm first-year aging limit is 80 Hz and the A7U’s 3 ppm is 48 Hz, a difference of 32 Hz. These are first-year limits under the stated conditions. They do not predict the same annual drift during continuous high-temperature operation. Suppose a project has allocated the initial, board-load, and temperature terms separately and reserved 64 Hz, or 4 ppm, for first-year component aging. The A7U leaves 16 Hz within that allowance. The A7T exceeds it by 16 Hz. Adjust the documented budget before approving on the basis of a changed system limit or a verified correction mechanism.

For a system that can reach 110 °C briefly, establish whether that is the actual operating temperature at the crystal. The listed enclosure temperature, processor junction temperature, and crystal environment refer to different points. If the project measures near the package, run representative power states and retain the sensor location and calibration. Evidence that the local temperature stays at or below 100 °C may allow reevaluation of A7T within its stated range. For conditions near or above 105 °C, a passing room-temperature reading from either 16 MHz passive crystal cannot close the review. Use a code with the specified performance in range or change the board conditions and verify them.

Distinguish storage from operation. The maximum storage rating is 125 °C for A7T and 150 °C for A7U. If a supplier says the older option supports 125 °C, ask whether that figure came from the storage row. Unpowered storage or shipment is different from an operating oscillator with a frequency requirement. Carry both rows into the change record to prevent another ambiguous maximum temperature from being passed around.

Record allowed substitutions against controlled specifications

Both marking drawings identify a logo, frequency, and production lot, with a possible added site mark. The frequency alone tells receiving only part of the identity. Establish A7T or A7U from the complete label and delivery record. If the purchasing system has a shared DSX321G entry, link each exact code to the approved board, temperature, and first-year limit in the substitute list. Engineering signs the restrictions. A third-party lab can verify initial tolerance and series resistance at room temperature. For aging, retain manufacturer data with a time condition and baseline or agree on an appropriate long-duration test.

Evaluate existing and candidate lots on the same fixture and retain the test conditions and board results. If the candidate satisfies the specified temperature and aging limits, proceed to first article on the approved PCB revision. If an A7T offer requires a waiver of the original aging or high-temperature requirement, define the affected products and shipping conditions and release only within written approval. The restriction must remain visible when stock is picked again. A change approved for one enclosure must not reach another work order by using the same family entry. Receiving and repair can use the full suffix and board history to recover the applicable limits.

If specimens lost their labels when the reel was split, frequency cannot sort them into two guaranteed grades. Quality can assess whether original receiving and lot records reliably restore traceability. Otherwise keep them in a pending or segregated status. Ask suppliers that send the data sheet and inspection report separately to tie each sample to the relevant document. A report without that relationship can support discussion, while the approval awaits written confirmation. If a temperature test later fails, the retained record can establish whether the planned suffix was installed.

References