An industrial Ethernet board needs a replacement PHY, and the offered part differs by only a few suffix letters. If a passive quartz crystal spans the old board's pins, check the difference between KSZ8081RNA and RND. Microchip states that RND has no crystal driver. Its 25 MHz reference requires an oscillator. A correctly specified passive 25 MHz crystal cannot supply a sustained clock to that input on its own.
Trace the clock from its source to the MAC
Mark on the schematic whether the source is a crystal feedback network or an active clock, then confirm where the PHY obtains the reference it sends to the MAC. The manufacturer explains that, in the applicable modes, these two variants can output 50 MHz at REF_CLK when clocked from 25 MHz. If the system uses a shared 50 MHz source, check distribution to the MAC and PHY. A 50 MHz MAC label does not establish the frequency of the old board's passive crystal.
Create separate build drawings for the crystal and load network and for the active source, supply, output, and input connection. After removing all power and restarting, check whether the PHY obtains a valid reference, then verify the expected MAC reference and reset order. Keep a known-good interface board and test a fixed peer, repeated cold starts, and sustained traffic beyond one register response.
For an unchanged-footprint substitution, flag the missing crystal driver for engineering review. If an active source is allowed, recheck board area, idle power, and wake recovery. Tie the exact PHY suffix to its clock components on the purchase order rather than writing only “KSZ8081 compatible, 25 MHz.”Microchip KSZ8081 and KSZ8091 variant guidance