An inspector selects 8 pF for a 16 MHz 3225 crystal and intends to compare frequency and effective resistance from the same sweep. Kyocera's dedicated specification for CX3225GA16000D0PTVCC separates the conditions. Frequency uses an IEC π-network fixture, 8 pF and 10 µW. ESR uses the same fixture and drive but the load column says Series. If the instrument has one load setting, establish exactly what it does to each reading.
Match the measurement state to the parameter
The part is a 16 MHz fundamental-mode crystal with a 100 Ω ESR limit and ±50 ppm initial tolerance at the stated room-temperature condition. If one complex-impedance sweep is fitted to obtain several quantities, establish which output refers to series resonance and which to frequency at the specified load. Effective resistance at one loaded condition cannot be used as the specified series ESR without an appropriate conversion.
Verify the procedure with a known reference unit and record instrument mode, drive control, fixture compensation, and both results. Retest a borderline sample under the manufacturer's conditions. Changing load to bring frequency into limits does not establish acceptance for resistance. Test the complete part number against guarantees under the agreed conditions.
Label board operating frequency separately from bare-crystal fixture results. The assembly includes loop and loading effects and cannot substitute for the incoming test. Attach the measurement-conditions page for supplier comparison and avoid using another CX3225GA option to characterize this high-temperature part.Kyocera CX3225GA16000D0PTVCC dedicated specification