Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

Can an 8 pF Kyocera crystal replace CX2016SA25000F0FRZC1 on a Valens camera board?

Suppose a camera board using Valens VA7031 has CX2016SA25000F0FRZC1 on its original BOM. The second-source quote says only “Kyocera 2016, 25 MHz, automotive.” Those descriptors fit multiple devices in Kyocera’s range. The manufacturer’s IC matching table puts F0FRZC1 on the VA7044/VA7031 row with 25 MHz and 10 pF load capacitance. Kyocera also lists a CX2016SA25000D0GSS option with an 8 pF load. Compare the full ordering numbers in both quotes to the matching table and approval drawings, and confirm which option actually arrived before adjusting board capacitors.

Use exact-part documents to resolve a family-level description

Kyocera’s short F0FRZC1 document is explicitly preliminary. DigiKey also hosts the 11-page Kyocera-issued approval drawing UKY1C-H1-23063-00[37]. Both show 10.0 pF, fundamental operation, ±10 ppm room-temperature initial tolerance, and ±35 ppm from −40 to +105 °C with respect to the 25 °C result. The full drawing gives ±2 ppm first-year aging and a 100 Ω maximum equivalent series resistance. Its cover lists AEC-Q200 compliance. If the quote conflicts with the controlled document, obtain the latest valid specification covering the full ordering number before approving procurement.

A separate manufacturer page covers CX2016SA25000D0GSS with wildcard suffixes. It gives 8.0 pF, ±15 ppm at 25 °C, ±50 ppm temperature characteristics, −40 to +125 °C operation, and AEC-Q200. This option extends the upper operating temperature and allows wider initial and thermal deviations. If procurement collapses temperature, accuracy, load capacitance, and qualification into one “automotive” field, the same stock code can issue two different electrical configurations. A project requiring operation at 125 °C needs a board-level timing budget and interface approval for that requirement.

For repair stock, a 25000 top marking helps confirm nominal frequency. Section 6 of the full drawing also shows serial, date, and internal identification information. Use the original reel or controlled split-lot label to associate the full ordering code with the date lot. Entering the top-side frequency in the manufacturer part-number field loses that link. If only the fitted part remains, recover the oscillator reference designator from the original board number, BOM, and approved change record. Frequency grouping can support an investigation when that chain is incomplete, and original project records are still needed to establish spare-part identity.

Inspect frequency and ESR under their respective fixture conditions

Section 5 of the full approval drawing measures F0FRZC1 frequency in an IEC pi-network fixture with a 10.0 pF load at 10 µW. ESR uses the same fixture category and drive level, with the load condition set to series. Selecting 10 pF for both does not reproduce the two manufacturer test definitions. If a lot shows a shifted frequency distribution, check whether the fixture was left on a previous 8 pF job. Rerun a known reference sample and verify the timebase. Record fixture settings, drive level, temperature, and the check after switching fixtures so that the supplier can repeat the measurement.

Record post-reflow results separately. Section 10 lists ±2 ppm shift under the specified reflow conditions and two reflow passes. If the crystal goes on the first side of a double-sided board, return the assembly to the same temperature to compare results after the second pass. If a repair introduces another heating cycle, review cumulative exposure against the exact-part document. An earlier pass at two reflows cannot approve additional heating by itself. Retaining an unmounted sample from the same lot for comparison helps distinguish instrument or temperature drift, reflow-related shift, and a change due to board loading.

A 2 pF change in load may require a larger change at each capacitor

For an oscillator circuit with a capacitor from each crystal terminal to ground, a first approximation is CL ≈ C1C2/(C1+C2)+Cp. Assume 2.5 pF equivalent parasitic capacitance. Two 15 pF capacitors give a combined load of 10 pF. In the same approximation, reaching 8 pF requires about 11 pF on each side. Real boards also involve the chip’s internal capacitance, routing, package, and batch variation. Some programmable capacitors change settings after power-up. The 15 pF and 11 pF values here are examples. Use the IC documentation and measurements to select the installed values.

The frequency shift from a load change also depends on the crystal’s motional and shunt capacitance. A 2 pF difference in specified load does not establish a universal ppm-per-pF rule. To assess whether a board can support both choices, sweep several capacitor settings near each part’s target, using one timebase, the same firmware, and the same board temperature. Plot the measured board frequency against capacitor setting. Holding the other variables fixed helps distinguish systematic load pulling from a shift associated with soldering during a new assembly.

Calculate the camera link’s frequency budget before changing the component. Assume a project allows ±60 ppm at its 25 MHz board reference over −40 to +105 °C for the first year. Adding the F0FRZC1 initial, thermal, and first-year limits gives 10+35+2=47 ppm, or about 1,175 Hz. The hypothetical board has 13 ppm left. Reserving an additional 2 ppm for reflow shift leaves only 11 ppm for load error, instrument uncertainty, and board variation. The 8 pF option reaches 65 ppm, or about 1,625 Hz, from the initial and thermal allowances alone. This calculation supports holding off on a direct substitution under the assumed project limit of ±60 ppm.

Board qualification should also exercise cold startup and the supply limits. Section 11 of Kyocera’s F0FRZC1 drawing recommends negative resistance of ten times the crystal’s ESR. Using the 100 Ω maximum for design review corresponds to a 1 kΩ magnitude target. Follow the crystal and IC vendors’ measurement methods and record the load network, chamber temperature, minimum supply, and startup time. Taking frequency from an allowed buffered output helps reduce the extra capacitance of probing the high-impedance oscillator node. If the team approves an alternate, retain cold startup, temperature cycling, and link-state evidence for the applicable board revision, together with the reel identification needed to reproduce a result.

If the finished unit only reports link lock, instrument the validation board to log time to lock, reset count, and reference clock error. Suppose a room-temperature sample works with two 15 pF capacitors but occasionally times out during cold startup after switching to an 8 pF crystal. Keep the same silicon, firmware, and supply, and compare the original configuration, the alternate with the original load, and the alternate with its own tuned load. Use the same unpowered interval and chamber soak for each start. A sample that locks has demonstrated a single successful start. Volume approval also depends on the frequency window, startup margin, and repeatability.

Capture the crystal and its load-capacitor changes on the same engineering change order. That allows one line to issue both configurations to the correct board revisions and tells repair staff whether a crystal swap requires changing both capacitors or a software setting. Put the full manufacturer number and specification revision on the shipment report and retain component and assembled-board test records. If board approval only covered the pilot temperature range, add evidence at the actual operating limits before a volume cutover.

Manufacturer documents

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.