When deriving a switching power supply's synchronization clock from the system oscillator, it may seem simpler to remove the original frequency-setting resistor and connect the divided clock directly. The LM25116 RT/SYNC pin sets the internal free-running frequency and also accepts external synchronization. The external clock must arrive before the internal oscillator starts its next cycle. The system also needs a predictable free-running frequency during power sequencing or when the external clock is disabled.
Choose the synchronization frequency, then calculate the free-running setting
Dividing 4.096 MHz by eight gives 512 kHz. The manufacturer calls for a nominal free-running frequency about 15% below the external clock. That is approximately 435 kHz here. Use the data sheet's RT formula to select the resistor and account for tolerance. Check the permitted operating range under the actual supply conditions as well. A 512 kHz logic output at the divider does not establish synchronization. Verify the pulses at RT/SYNC.
The manual recommends capacitor-coupling a positive edge into this pin and gives the detection threshold and an example source amplitude. A square wave at a low-voltage divider does not guarantee that the coupled peak reaches the threshold. Check the waveform and ratings at the pin with the recommended connection. Observe switching periods before clock arrival, during normal synchronization, and after clock removal.
Triggering only in steady operation can miss switching-frequency changes during sleep or reset. Capture the synchronization-source enable and power-switch node together, and verify the operating mode at the actual load. Set acceptance ranges for switching frequency and supply behavior both with and without synchronization. This gives a basis for later oscillator or divider changes.TI LM25116 data sheet, Section 6.3.4