A synchronization board uses LMK05318B and already lists a BAW VCO. That does not make the external reference arbitrary. TI says the XO input references the internal analog PLL and sets output frequency accuracy and stability in free-run and holdover. Generating a low-noise high-frequency clock internally and maintaining long-term frequency when the external reference disappears are separate functions.
Work backward from allowable time error to the purchasing target
Suppose a system permits 100 µs of accumulated error for one hour after losing the reference. Ignoring other errors, the average relative frequency budget is 100 µs ÷ 3600 s, or about 0.028 ppm. This is an ideal upper bound. Allow for initial error on entering holdover, temperature change, aging, calibration, and algorithm behavior before deciding whether the existing TCXO or a candidate OCXO works. One initial room-temperature ppm value does not cover the whole holdover interval.
Keep both the local source and synchronizer measurement points
Record lock conditions and temperature before removing the external reference. After disconnecting it, track the local source and system output timing error together. The final output alone cannot readily distinguish local frequency drift from holdover settings and switching transients. Use the same synchronizer settings, supply, and temperature profile for both candidates, and state whether calibration was applied.
List the synchronizer and local XO separately in the purchasing sheet. Request actual supply, output compatibility, and operating-condition data. A lower-power TCXO is suitable if it meets the full budget; a holdover label by itself does not determine whether an oven-controlled part is needed. TI LMK05318B XO input and operating modes