LMK1C1104EVM shows 50 MHz at Y0 but nothing at Y4. Is that output faulty or unpopulated?

With 50 MHz applied to the board, a clock appears at one output but not at the position labeled Y4. TI’s board layout accommodates compatible devices with up to eight outputs. The fitted LMK1C1104 has four, Y0 through Y3. Extra connector labels do not identify active outputs on this assembly.

Read the complete device marking and board ID, then map the device outputs to connectors. Use the same known-good cable on Y0 through Y3. If only one of those fails, check its solder joints, connector, and load. If none work, check CLK_In, device power, and the enable jumper. The guide enables output by shorting pins 2 and 3 on J3 and disables it when the enable is floating or low. A common enable fault cannot selectively affect an absent Y4.

The board provides output pull-up and pull-down load positions that are unpopulated by default. If Y0 through Y3 all have the correct frequency but different amplitudes, check for fitted loads and inconsistent instrument settings. Record populated and empty pads together so later testers do not mistake modifications for factory differences.

Report which of the four fitted outputs passed. If eight are needed, verify the appropriate device and board compatibility. Software enable cannot add physical outputs. Mark unused channels on the fixture drawing so automated tests exclude them from yield calculations.TI LMK1C1104EVM manual, Sections 5 and 6